IPIP: A new approach to inverse planning for HDR brachytherapy by directly optimizing dosimetric indices.

Timmy Siauw1, Adam Cunha, Alper Atamtürk, I-Chow Hsu, Jean Pouliot, Ken Goldberg.   

Abstract

PURPOSE: Many planning methods for high dose rate (HDR) brachytherapy require an iterative approach. A set of computational parameters are hypothesized that will give a dose plan that meets dosimetric criteria. A dose plan is computed using these parameters, and if any dosimetric criteria are not met, the process is iterated until a suitable dose plan is found. In this way, the dose distribution is controlled by abstract parameters. The purpose of this study is to develop a new approach for HDR brachytherapy by directly optimizing the dose distribution based on dosimetric criteria.
METHODS: The authors developed inverse planning by integer program (IPIP), an optimization model for computing HDR brachytherapy dose plans and a fast heuristic for it. They used their heuristic to compute dose plans for 20 anonymized prostate cancer image data sets from patients previously treated at their clinic database. Dosimetry was evaluated and compared to dosimetric criteria.
RESULTS: Dose plans computed from IPIP satisfied all given dosimetric criteria for the target and healthy tissue after a single iteration. The average target coverage was 95%. The average computation time for IPIP was 30.1 s on an Intel(R) Core 2 Duo CPU 1.67 GHz processor with 3 Gib RAM.
CONCLUSIONS: IPIP is an HDR brachytherapy planning system that directly incorporates dosimetric criteria. The authors have demonstrated that IPIP has clinically acceptable performance for the prostate cases and dosimetric criteria used in this study, in both dosimetry and runtime. Further study is required to determine if IPIP performs well for a more general group of patients and dosimetric criteria, including other cancer sites such as GYN.

Entities:  

Mesh:

Year:  2011        PMID: 21859003     DOI: 10.1118/1.3598437

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Bi-objective optimization of catheter positions for high-dose-rate prostate brachytherapy.

Authors:  Marjolein C van der Meer; Peter A N Bosman; Yury Niatsetski; Tanja Alderliesten; Niek van Wieringen; Bradley R Pieters; Arjan Bel
Journal:  Med Phys       Date:  2020-10-21       Impact factor: 4.071

2.  An extended dose-volume model in high dose-rate brachytherapy - Using mean-tail-dose to reduce tumor underdosage.

Authors:  Björn Morén; Torbjörn Larsson; Åsa Carlsson Tedgren
Journal:  Med Phys       Date:  2019-05-15       Impact factor: 4.071

3.  A survey of quality control practices for high dose rate (HDR) and pulsed dose rate (PDR) brachytherapy in the United Kingdom.

Authors:  Antony L Palmer; Margaret Bidmead; Andrew Nisbet
Journal:  J Contemp Brachytherapy       Date:  2012-12-28

4.  Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques.

Authors:  Antony Palmer; David Bradley; Andrew Nisbet
Journal:  J Contemp Brachytherapy       Date:  2012-06-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.