Literature DB >> 21858857

Suture anchor versus screw fixation for greater tuberosity fractures of the humerus--a biomechanical study.

Cheng-Li Lin1, Chih-Kai Hong, I-Ming Jou, Chii-Jeng Lin, Fong-Chin Su, Wei-Ren Su.   

Abstract

Suture anchors and screws are commonly used for fixation of humeral greater tuberosity (GT) fractures in either arthroscopic or open surgeries, but no biomechanical studies have been performed to compare the strength of fixation constructs using these two implants. This cadaveric study aimed to compare the biomechanical strength of three different fixation constructs in the management of GT fractures: Double-Row Suture Anchor Fixation (DR); Suture-Bridge Technique using suture anchors and knotless suture anchors (SB); and Two-Screw Fixation (TS). The experimental procedure was designed to assess fracture displacement after cyclic loading, failure load, and failure mode of the fixation construct. Significant differences were found among the SB (321 N), DR (263 N), and TS (187 N) groups (SB > DR > TS, p < 0.05) in the mean force of cyclic loading to create 3 mm displacement. Regarding the mean force of cyclic loading to create 5 mm displacement and ultimate failure load, no significant difference was found between the DR (370 N, 480 N) and SB (399 N, 493 N) groups, but both groups achieved superior results compared with the TS group (249 N, 340 N) (p < 0.05). The results suggested that the suture anchor constructs would be stronger than the fixation construct using screws for the humeral GT fracture.
Copyright © 2011 Orthopaedic Research Society.

Entities:  

Mesh:

Year:  2011        PMID: 21858857     DOI: 10.1002/jor.21530

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  12 in total

1.  Arthroscopic Treatment of Greater Tuberosity Avulsion Fractures.

Authors:  Jonathan A Godin; J Christoph Katthagen; Erik M Fritz; Jonas Pogorzelski; Peter J Millett
Journal:  Arthrosc Tech       Date:  2017-06-12

Review 2.  Surgical fixation of isolated greater tuberosity fractures of the humerus- systematic review and meta-analysis.

Authors:  Sachin Kumar; Arya Mishra; Hemant Singh; David Clark; Marius Espag; Amol Tambe
Journal:  J Clin Orthop Trauma       Date:  2021-10-27

3.  Arthroscopic-assisted plate fixation for displaced large-sized comminuted greater tuberosity fractures of proximal humerus: a novel surgical technique.

Authors:  Sang-Eun Park; Jae-Jung Jeong; Karnav Panchal; Jong-Yun Lee; Hyung-Ki Min; Jong-Hun Ji
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-09-29       Impact factor: 4.342

4.  Arthroscopic Reduction and Fixation With a Knotless Double-Row Construct Provides Good Results for Displaced Greater Tuberosity Fractures.

Authors:  Mohammad Bahman; Vanessa Costil; Mathilde Gaume; Marc-Antoine Rousseau; Patrick Boyer
Journal:  Arthrosc Sports Med Rehabil       Date:  2021-03-11

5.  Achilles tenodesis for calcaneal insufficiency avulsion fractures associated with diabetes mellitus.

Authors:  Youngrak Choi; Young-Woo Kwon; Young-Suk Sim; Taeho Kim; Dayoung Song; Soohyun Lee
Journal:  J Orthop Surg Res       Date:  2017-12-13       Impact factor: 2.359

6.  Biomechanical Analysis of the Fixation Strength of a Novel Plate for Greater Tuberosity Fractures.

Authors:  Aristotelis Kaisidis; Panagiotis G Pantos; Dimitrios Bochlos; Horst Lindner
Journal:  Open Orthop J       Date:  2018-06-29

7.  Arthroscopic fixation of humeral greater tuberosity fracture using a W-shaped suture.

Authors:  Xiaocong Lin; Xiuxi Huang; Kaibin Fang; Zhangsheng Dai
Journal:  J Orthop Surg Res       Date:  2020-11-23       Impact factor: 2.359

8.  Augmented cerclage wire improves the fixation strength of a two-screw construct for humerus split type greater tuberosity fracture: a biomechanical study.

Authors:  Chao-Jui Chang; Wei-Ren Su; Kai-Lan Hsu; Chih-Kai Hong; Fa-Chuan Kuan; Chih-Hsun Chang; Cheng-Li Lin
Journal:  BMC Musculoskelet Disord       Date:  2021-04-12       Impact factor: 2.362

9.  Minimally invasive open reduction of greater tuberosity fractures by a modified suture bridge procedure.

Authors:  Ling-Peng Kong; Juan-Juan Yang; Fu Wang; Fan-Xiao Liu; Yong-Liang Yang
Journal:  World J Clin Cases       Date:  2022-01-07       Impact factor: 1.337

10.  Single versus double row suture anchor fixation for greater tuberosity fractures - a biomechanical study.

Authors:  Gernot Seppel; Tim Saier; Frank Martetschläger; Johannes E Plath; Alberto Guevara-Alvarez; Julia Henschel; Martin Winkler; Peter Augat; Andreas B Imhoff; Stefan Buchmann
Journal:  BMC Musculoskelet Disord       Date:  2017-12-01       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.