Literature DB >> 21856254

A quantitative LC-MS/MS method for comparative analysis of capture-antibody affinity toward protein antigens.

Mark S Lowenthal1, Hugo Gasca-Aragon, John E Schiel, Nathan G Dodder, David M Bunk.   

Abstract

A mass spectrometry-based antibody selection procedure was developed to evaluate optimal 'capture' monoclonal antibodies that can be used in a variety of analytical measurement applications. The isotope-dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) methodology is based on the use of multiple-reaction monitoring of tryptic peptide fragments derived from protein antigens. A panel of monoclonal antibodies (mAb) was evaluated based on a quantitative determination of relative binding affinity to human cardiac troponin I following immunoprecipitation. Dissociation constants (K(d)) were determined for 'bound mAb-antigen' vs. 'unbound antigen' using non-linear regression analysis. Relative quantification of both antigen and antibody was based on the use of stable isotope-labeled synthetic peptides as internal standards. Optimal 'capture' mAbs were determined through evaluation of relative K(d) constants of all monitored peptide transitions. A panel of six pre-screened candidate capture mAbs was concluded to consist of two subsets of mAbs, each with statistically equivalent K(d) constants as determined using NIST Standard Reference Material (SRM) 2921 - Human Cardiac Troponin Complex. This ID LC-MS/MS method is shown to be capable of quantitatively differentiating mAbs based on relative binding affinities. Selection of optimal capture mAbs can be applied toward a number of analytical applications which require metrological traceability and unbiased quantification. Published by Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21856254     DOI: 10.1016/j.jchromb.2011.07.037

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  3 in total

1.  Quantification of cardiac troponin I in human plasma by immunoaffinity enrichment and targeted mass spectrometry.

Authors:  Nicole A Schneck; Karen W Phinney; Sang Bok Lee; Mark S Lowenthal
Journal:  Anal Bioanal Chem       Date:  2018-03-01       Impact factor: 4.142

Review 2.  Review of the Use of Liquid Chromatography-Tandem Mass Spectrometry in Clinical Laboratories: Part I-Development.

Authors:  Brian A Rappold
Journal:  Ann Lab Med       Date:  2022-03-01       Impact factor: 3.464

3.  Spiegelmer-Based Sandwich Assay for Cardiac Troponin I Detection.

Authors:  Zoltán János Tolnai; Judit András; Zsuzsanna Szeitner; Krisztina Percze; László Ferenc Simon; Róbert E Gyurcsányi; Tamás Mészáros
Journal:  Int J Mol Sci       Date:  2020-07-14       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.