Literature DB >> 21853255

Design and synthesis of a terbium(III) complex-based luminescence probe for time-gated luminescence detection of mercury(II) ions.

Guanfeng Cui1, Zhiqiang Ye, Run Zhang, Guilan Wang, Jingli Yuan.   

Abstract

Time-gated luminescence detection technique using lanthanide complexes as luminescent probes is a useful and highly sensitive method. However, the effective application of this technique is limited by the lack of the target-responsive luminescent lanthanide complexes that can specifically recognize various analytes in aqueous solutions. In this work, a dual-functional ligand that can form a stable complex with Tb(3+) and specifically recognize Hg(2+) ions in aqueous solutions, N,N,N(1),N(1)-{[2,6-bis(3'-aminomethyl-1'-pyrazolyl)-4-[N,N-bis(3″,6″-dithiaoctyl)-aminomethyl]- pyridine]} tetrakis(acetic acid) (BBAPTA), has been designed and synthesized. The luminescence of its Tb(3+) complex is weak, but can be effectively enhanced upon reaction with Hg(2+) ions in aqueous solutions. The luminescence response investigations of BBAPTA-Tb(3+) to various metal ions indicate that the complex has a good luminescence sensing selectivity for Hg(2+) ions, but not for other metal ions. Thus a highly sensitive time-gated luminescence detection method for Hg(2+) ions was developed by using BBAPTA-Tb(3+) as a luminescent probe. The dose-dependent luminescence enhancement of the probe shows a good linearity with a detection limit of 17 nM for Hg(2+) ions. These results demonstrated the efficacy and advantages of the new Tb(3+) complex-based luminescence probe for the sensitive and selective detection of Hg(2+) ions.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21853255     DOI: 10.1007/s10895-011-0956-6

Source DB:  PubMed          Journal:  J Fluoresc        ISSN: 1053-0509            Impact factor:   2.217


  31 in total

1.  Detection of mercury in fish organs with a two-photon fluorescent probe.

Authors:  Chang Su Lim; Dong Won Kang; Yu Shun Tian; Ji Hee Han; Hye Lim Hwang; Bong Rae Cho
Journal:  Chem Commun (Camb)       Date:  2010-02-02       Impact factor: 6.222

2.  Divergent approach to a large variety of versatile luminescent lanthanide complexes.

Authors:  Pascal Kadjane; Matthieu Starck; Franck Camerel; Diana Hill; Niko Hildebrandt; Raymond Ziessel; Loïc J Charbonnière
Journal:  Inorg Chem       Date:  2009-06-01       Impact factor: 5.165

3.  The determination of methylmercury in real samples using organically capped mesoporous inorganic materials capable of signal amplification.

Authors:  Estela Climent; M Dolores Marcos; Ramón Martínez-Máñez; Félix Sancenón; Juan Soto; Knut Rurack; Pedro Amorós
Journal:  Angew Chem Int Ed Engl       Date:  2009       Impact factor: 15.336

Review 4.  Lanthanide luminescence for biomedical analyses and imaging.

Authors:  Jean-Claude G Bünzli
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

5.  An easily prepared hypersensitive water-soluble fluorescent probe for mercury(II) ions.

Authors:  Hong-Wei Li; Yue Li; Yong-Qiang Dang; Li-Jun Ma; Yuqing Wu; Guangfeng Hou; Lixin Wu
Journal:  Chem Commun (Camb)       Date:  2009-06-12       Impact factor: 6.222

Review 6.  Mercury levels along the food chain and risk for exposed populations.

Authors:  A Renzoni; F Zino; E Franchi
Journal:  Environ Res       Date:  1998-05       Impact factor: 6.498

7.  Cognitive performance of children prenatally exposed to "safe" levels of methylmercury.

Authors:  P Grandjean; P Weihe; R F White; F Debes
Journal:  Environ Res       Date:  1998-05       Impact factor: 6.498

8.  Development of a novel terbium(III) chelate-based luminescent probe for highly sensitive time-resolved luminescence detection of hydroxyl radical.

Authors:  Guanfeng Cui; Zhiqiang Ye; Jinxue Chen; Guilan Wang; Jingli Yuan
Journal:  Talanta       Date:  2011-03-04       Impact factor: 6.057

9.  Development of a terbium complex-based luminescent probe for imaging endogenous hydrogen peroxide generation in plant tissues.

Authors:  Zhiqiang Ye; Jinxue Chen; Guilan Wang; Jingli Yuan
Journal:  Anal Chem       Date:  2011-05-11       Impact factor: 6.986

10.  A multiresponsive two-arm ferrocene-based chemosensor molecule for selective detection of mercury.

Authors:  Tomás Romero; Antonio Caballero; Arturo Espinosa; Alberto Tárraga; Pedro Molina
Journal:  Dalton Trans       Date:  2009-01-30       Impact factor: 4.390

View more
  2 in total

Review 1.  Lanthanide probes for bioresponsive imaging.

Authors:  Marie C Heffern; Lauren M Matosziuk; Thomas J Meade
Journal:  Chem Rev       Date:  2013-12-13       Impact factor: 60.622

Review 2.  X-ray fluorescence imaging of metals and metalloids in biological systems.

Authors:  Run Zhang; Li Li; Yasmina Sultanbawa; Zhi Ping Xu
Journal:  Am J Nucl Med Mol Imaging       Date:  2018-06-05
  2 in total