Literature DB >> 21852741

Phosphine-free synthesis of high-quality reverse type-I ZnSe/CdSe core with CdS/Cd(x)Zn(1 - x)S/ZnS multishell nanocrystals and their application for detection of human hepatitis B surface antigen.

Huaibin Shen1, Hang Yuan, Jin Zhong Niu, Shasha Xu, Changhua Zhou, Lan Ma, Lin Song Li.   

Abstract

Highly photoluminescent (PL) reverse type-I ZnSe/CdSe nanocrystals (NCs) and ZnSe/CdSe/CdS/Cd(x)Zn(1 - x)S/ZnS core/multishell NCs were successfully synthesized by a phosphine-free method. By this low-cost, 'green' synthesis route, more than 10 g of high-quality ZnSe/CdSe/CdS/Cd(x)Zn(1 - x)S/ZnS NCs were synthesized in a large scale synthesis. After the overgrowth of a CdS/Cd(x)Zn(1 - x)S/ZnS multishell on ZnSe/CdSe cores, the PL quantum yields (QYs) increased from 28% to 75% along with the stability improvement. An amphiphilic oligomer was used as a surface coating agent to conduct a phase transfer experiment, core/multishell NCs were dissolved in water by such surface modification and the QYs were still kept above 70%. The as-prepared water dispersible ZnSe/CdSe/CdS/Cd(x)Zn(1 - x)S/ZnS core/multishell NCs not only have high fluorescence QYs but also are extremely stable in various physiological conditions. Furthermore, a biosensor system (lateral flow immunoassay system, LFIA) for the detection of human hepatitis B surface antigen (HBsAg) was developed by using this water-soluble core/multishell NCs as a fluorescent label and a nitrocellulose filter membrane for lateral flow. The result showed that such ZnSe/CdSe/CdS/Cd(x)Zn(1 - x)S/ZnS core/multishell NCs were excellent fluorescent labels to detect HBsAg. The sensitivity of HBsAg detection could reach as high as 0.05 ng ml( - 1).

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21852741     DOI: 10.1088/0957-4484/22/37/375602

Source DB:  PubMed          Journal:  Nanotechnology        ISSN: 0957-4484            Impact factor:   3.874


  3 in total

1.  Development of a smartphone-based rapid dual fluorescent diagnostic system for the simultaneous detection of influenza A and H5 subtype in avian influenza A-infected patients.

Authors:  Seon-Ju Yeo; Homan Kang; Tung Duy Dao; Bui Thi Cuc; Anh Thi Viet Nguyen; Trinh Thi Thuy Tien; Nguyen Le Khanh Hang; Hoang Vu Mai Phuong; Le Thi Thanh; Le Quynh Mai; Yoonhyuk Rah; Kyoungsik Yu; Ho-Joon Shin; Chom-Kyu Chong; Hak Soo Choi; Hyun Park
Journal:  Theranostics       Date:  2018-11-29       Impact factor: 11.556

Review 2.  Lateral flow assays for viruses diagnosis: Up-to-date technology and future prospects.

Authors:  Bahar Ince; Mustafa Kemal Sezgintürk
Journal:  Trends Analyt Chem       Date:  2022-07-05       Impact factor: 14.908

3.  Multiplexed detection of influenza A virus subtype H5 and H9 via quantum dot-based immunoassay.

Authors:  Feng Wu; Hang Yuan; Changhua Zhou; Mao Mao; Qian Liu; Huaibin Shen; Yu Cen; Zhifeng Qin; Lan Ma; Ling Song Li
Journal:  Biosens Bioelectron       Date:  2015-10-09       Impact factor: 10.618

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.