Literature DB >> 21851106

Bead-based competitive fluorescence immunoassay for sensitive and rapid diagnosis of cyanotoxin risk in drinking water.

Hye-Weon Yu1, Am Jang, Lan Hee Kim, Sung-Jo Kim, In S Kim.   

Abstract

Due to the increased occurrence of cyanobacterial blooms and their toxins in drinking water sources, effective management based on a sensitive and rapid analytical method is in high demand for security of safe water sources and environmental human health. Here, a competitive fluorescence immunoassay of microcystin-LR (MCYST-LR) is developed in an attempt to improve the sensitivity, analysis time, and ease-of-manipulation of analysis. To serve this aim, a bead-based suspension assay was introduced based on two major sensing elements: an antibody-conjugated quantum dot (QD) detection probe and an antigen-immobilized magnetic bead (MB) competitor. The assay was composed of three steps: the competitive immunological reaction of QD detection probes against analytes and MB competitors, magnetic separation and washing, and the optical signal generation of QDs. The fluorescence intensity was found to be inversely proportional to the MCYST-LR concentration. Under optimized conditions, the proposed assay performed well for the identification and quantitative analysis of MCYST-LR (within 30 min in the range of 0.42-25 μg/L, with a limit of detection of 0.03 μg/L). It is thus expected that this enhanced assay can contribute both to the sensitive and rapid diagnosis of cyanotoxin risk in drinking water and effective management procedures.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21851106     DOI: 10.1021/es201333f

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  4 in total

1.  A bead-based fluorescence immunosensing technique enabled by the integration of Förster resonance energy transfer and optoelectrokinetic concentration.

Authors:  Jhih-Cheng Wang; Hu-Yao Ku; Dar-Bin Shieh; Han-Sheng Chuang
Journal:  Biomicrofluidics       Date:  2016-01-28       Impact factor: 2.800

2.  Magnetic bead-based colorimetric immunoassay for aflatoxin B1 using gold nanoparticles.

Authors:  Xu Wang; Reinhard Niessner; Dietmar Knopp
Journal:  Sensors (Basel)       Date:  2014-11-14       Impact factor: 3.576

3.  Phosphorescent immunosensor for simple and sensitive detection of microcystin-LR in water.

Authors:  Jin Qin; Xiaojie Sun; Dongxia Li; Guiqin Yan
Journal:  RSC Adv       Date:  2019-04-25       Impact factor: 3.361

Review 4.  Immunoassays and biosensors for the detection of cyanobacterial toxins in water.

Authors:  Michael G Weller
Journal:  Sensors (Basel)       Date:  2013-11-05       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.