Literature DB >> 21843027

The effect of dentin desensitizer on shear bond strength of conventional and self-adhesive resin luting cements after aging.

B Stawarczyk1, R Hartmann, L Hartmann, M Roos, M Ozcan, I Sailer, C H F Hämmerle.   

Abstract

This study tested the impact of Gluma Desensitizer on the shear bond strength (SBS) of two conventional (RelyX ARC, Panavia 21) and two self-adhesive (RelyX Unicem, G-Cem) resin luting cements after water storage and thermocycling. Human third molars (N=880) were embedded in acrylic resin. The buccal dentin was exposed. Teeth were randomly divided into four main groups, and the following cements were adhered: 1) RelyX ARC, 2) Panavia 21, 3) RelyX Unicem, and 4) G-Cem. In half of the teeth in each group, dentin was treated with Gluma Desensitizer. In the conventional cement groups, the corresponding etchant and adhesive systems were applied. SBS of the cements was tested after 1 hour (initial); at 1, 4, 9, 16, and 25 days of water storage; and at 1, 4, 9, 16, and 25 days of thermocycling. SBS data were analyzed by one-way analysis of variance (ANOVA); this was followed by the post hoc Scheffé test and a t-test. Overall, the highest mean SBS (MPa) was obtained by RelyX ARC (ranging from 14.6 ± 3.9 to 17.6 ± 5.2) and the lowest by Panavia 21 in combination with Gluma Desensitizer (ranging from 0.0 to 2.9 ± 1.0). All tested groups with and without desensitizer showed no significant decrease after aging conditions compared with baseline values (p>0.05). Only the Panavia 21/Gluma Desensitizer combination showed a significant decrease after 4 days of thermocyling compared with initial values and 1 day thermocycling. Self-adhesive cements with Gluma Desensitizer showed increased SBS after aging conditions (ranging from 7.4 ± 1.4 to 15.2 ± 3) compared with groups without desensitizer (ranging from 2.6 ± 1.2 to 8.8 ± 2.9). No cohesive failures in dentin were observed in any of the test groups. Although self-adhesive cements with and without desensitizer presented mainly adhesive failures after water storage (95.8%) and thermocyling (100%), conventional cement (RelyX ARC) showed mainly mixed failures (90.8% and 89.2%, after water storage and thermocyling, respectively). Application of the Gluma Desensitizer to dentin before cementation had a positive effect on the SBS of self-adhesive cements.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21843027     DOI: 10.2341/10-292-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  10 in total

1.  Influence of proximal box elevation on bond strength of composite inlays.

Authors:  Dayana Da Silva Gonçalves; María Cura; Laura Ceballos; Mª Victoria Fuentes
Journal:  Clin Oral Investig       Date:  2016-03-11       Impact factor: 3.573

2.  Effect of theobromine-containing toothpaste on dentin tubule occlusion in situ.

Authors:  Bennett T Amaechi; Sapna M Mathews; Poornima K Mensinkai
Journal:  Clin Oral Investig       Date:  2014-03-27       Impact factor: 3.573

Review 3.  Current management of dentin hypersensitivity.

Authors:  Patrick R Schmidlin; Phlipp Sahrmann
Journal:  Clin Oral Investig       Date:  2012-12-30       Impact factor: 3.573

4.  The effect of dentin desensitizers and Nd:YAG laser pre-treatment on microtensile bond strength of self-adhesive resin cement to dentin.

Authors:  Ozlem Acar; Duygu Tuncer; Bulem Yuzugullu; Cigdem Celik
Journal:  J Adv Prosthodont       Date:  2014-04-22       Impact factor: 1.904

5.  HF etching of CAD/CAM materials: influence of HF concentration and etching time on shear bond strength.

Authors:  Antonio Straface; Lena Rupp; Aiste Gintaute; Jens Fischer; Nicola U Zitzmann; Nadja Rohr
Journal:  Head Face Med       Date:  2019-08-08       Impact factor: 2.151

6.  Effect of Different Desensitizers on Shear Bond Strength of Self-Adhesive Resin Cements to Dentin.

Authors:  Alejandro Elizalde-Hernández; Louis Hardan; Rim Bourgi; Cristina Pereira Isolan; Andressa Goicochea Moreira; J Eliezer Zamarripa-Calderón; Evandro Piva; Carlos Enrique Cuevas-Suárez; Walter Devoto; Ahmed Saad; Patrycja Proc; Monika Lukomska-Szymanska
Journal:  Bioengineering (Basel)       Date:  2022-08-07

7.  The effect of a desensitizer and CO2 laser irradiation on bond performance between eroded dentin and resin composite.

Authors:  Meng Ding; Sang-Wan Shin; Min-Soo Kim; Jae-Jun Ryu; Jeong-Yol Lee
Journal:  J Adv Prosthodont       Date:  2014-06-24       Impact factor: 1.904

8.  The Retentive Strength of Cemented Zirconium Oxide Crowns after Dentin Pretreatment with Desensitizing Paste Containing 8% Arginine and Calcium Carbonate.

Authors:  Raphael Pilo; Noga Harel; Joseph Nissan; Shifra Levartovsky
Journal:  Int J Mol Sci       Date:  2016-03-25       Impact factor: 5.923

9.  Effect of GLUMA desensitizer on the retention of full metal crowns cemented with Rely X U200 self-adhesive cement.

Authors:  Shirin Lawaf; Ezatallah Jalalian; Roshanak Roshan; Arash Azizi
Journal:  J Adv Prosthodont       Date:  2016-10-21       Impact factor: 1.904

10.  Tooth surface treatment strategies for adhesive cementation.

Authors:  Nadja Rohr; Jens Fischer
Journal:  J Adv Prosthodont       Date:  2017-04-06       Impact factor: 1.904

  10 in total