Literature DB >> 21842583

Progress in ring array transducers for real-time 3D ultrasound guidance of cardiac interventional devices.

Edward D Light1, Victor Lieu, Stephen W Smith.   

Abstract

As a treatment for aortic stenosis, several companies have recently introduced prosthetic heart valves designed to be deployed through a catheter using an intravenous or transapical approach. This procedure can either take the place of open heart surgery with some ofthe devices or delay it with others. Real-time 3D ultrasound could enable continuous monitoring of these structures before, during and after deployment. We have developed a 2D ring array integrated with a 30 French catheter that is used for transapical prosthetic heart valve implantation. The transducer array was built using three 46 cm long flex circuits from MicroConnex (Snoqualmie, WA) which terminate in an interconnect that plugs directly into our system cable; thus, no cable soldering is required. This transducer consists of 210 elements at 0.157 mm interelement spacing and operates at 5 MHz. Average measured element bandwidth was 26% and average round-trip 50 ohm insertion loss was -58.1 dB after correcting for diffractive losses. The transducer was wrapped around the 1 cm diameter lumen of a heart-valve deployment catheter. Prosthetic heart valve images were obtained in water-tank studies.

Entities:  

Mesh:

Year:  2011        PMID: 21842583      PMCID: PMC3263761          DOI: 10.1177/016173461103300304

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  13 in total

1.  New fabrication techniques for ring-array transducers for real-time 3D intravascular ultrasound.

Authors:  Edward D Light; Victor Lieu; Stephen W Smith
Journal:  Ultrason Imaging       Date:  2009-10       Impact factor: 1.578

2.  Two dimensional arrays for real time 3D intravascular ultrasound.

Authors:  Edward D Light; Stephen W Smith
Journal:  Ultrason Imaging       Date:  2004-04       Impact factor: 1.578

3.  A miniaturized catheter 2-D array for real-time, 3-D intracardiac echocardiography.

Authors:  Warren Lee; Salim F Idriss; Patrick D Wolf; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-10       Impact factor: 2.725

4.  Real-time 3D transesophageal echocardiography.

Authors:  Eric C Pua; Salim F Idriss; Patrick D Wolf; S W Smith
Journal:  Ultrason Imaging       Date:  2004-10       Impact factor: 1.578

5.  3-D ultrasound imaging using a forward-looking CMUT ring array for intravascular/intracardiac applications.

Authors:  David T Yeh; Omer Oralkan; Ira O Wygant; Matthew O'Donnell; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-06       Impact factor: 2.725

6.  High-speed ultrasound volumetric imaging system. II. Parallel processing and image display.

Authors:  O T von Ramm; S W Smith; H R Pavy
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1991       Impact factor: 2.725

7.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

8.  Evaluation of patients with severe symptomatic aortic stenosis who do not undergo aortic valve replacement: the potential role of subjectively overestimated operative risk.

Authors:  David S Bach; Derrick Siao; Steven E Girard; Claire Duvernoy; Benjamin D McCallister; Sarah K Gualano
Journal:  Circ Cardiovasc Qual Outcomes       Date:  2009-10-27

9.  Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description.

Authors:  Alain Cribier; Helene Eltchaninoff; Assaf Bash; Nicolas Borenstein; Christophe Tron; Fabrice Bauer; Genevieve Derumeaux; Frederic Anselme; François Laborde; Martin B Leon
Journal:  Circulation       Date:  2002-12-10       Impact factor: 29.690

10.  Results of transfemoral or transapical aortic valve implantation following a uniform assessment in high-risk patients with aortic stenosis.

Authors:  Dominique Himbert; Fleur Descoutures; Nawwar Al-Attar; Bernard Iung; Gregory Ducrocq; Delphine Détaint; Eric Brochet; David Messika-Zeitoun; Fady Francis; Hassan Ibrahim; Patrick Nataf; Alec Vahanian
Journal:  J Am Coll Cardiol       Date:  2009-07-21       Impact factor: 24.094

View more
  3 in total

1.  Simultaneous Axial Multifocal Imaging Using a Single Acoustical Transmission: A Practical Implementation.

Authors:  Asaf Ilovitsh; Tali Ilovitsh; Josquin Foiret; Douglas N Stephens; Katherine W Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-05       Impact factor: 2.725

2.  Ring array transducers for real-time 3-D imaging of an atrial septal occluder.

Authors:  Edward D Light; Brooks D Lindsey; Joseph A Upchurch; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2012-06-12       Impact factor: 2.998

3.  Acoustical structured illumination for super-resolution ultrasound imaging.

Authors:  Tali Ilovitsh; Asaf Ilovitsh; Josquin Foiret; Brett Z Fite; Katherine W Ferrara
Journal:  Commun Biol       Date:  2018-01-22
  3 in total