Literature DB >> 21842311

Monitoring powder blend homogeneity using light-induced fluorescence.

Vineela Karumanchi1, Michael K Taylor, Kevin J Ely, William C Stagner.   

Abstract

Light-induced fluorescence (LIF) was evaluated as a process analytical technology to monitor blend homogeneity and establish a relationship with high-performance liquid chromatography (HPLC). Secondary aims for this study included a determination of blend steady-state, acceptable mixing time interval, and mixing end point. Also, identification of potential "dead spots" in the 124 L intermediate bulk container mixing tote was explored. Individual samples from 13 sample locations were collected at 0.25, 0.5, 0.75, 1, 2, 5, 10, and 20 min and analyzed using LIF and HPLC. LIF and HPLC methods showed similar mixing profiles. A coefficient of determination (R(2)) of 0.86 (p value < 0.0001) was obtained for a second-degree polynomial bivariate fit of LIF counts by HPLC percent label claim (%LC). A significant linear relationship was determined between LIF percent relative standard (%RSD) and HPLC %RSD (R(2) = 0.97, p < 0.0001). The LIF steady-state, acceptable mixing time interval, and mixing end point were determined to be 1-20, 2-20, and 2 min, respectively. The steady-state, acceptable mixing time interval, and mixing end point determined by HPLC were 1-20, 5-10, and 5 min, respectively. The Tukey-Kramer honestly significant difference analysis of HPLC %LC by sample location at 5 and 10 min mixing times showed that there was a statistical difference between the HPLC %LC group means at two blender locations.

Mesh:

Substances:

Year:  2011        PMID: 21842311      PMCID: PMC3225521          DOI: 10.1208/s12249-011-9667-1

Source DB:  PubMed          Journal:  AAPS PharmSciTech        ISSN: 1530-9932            Impact factor:   3.246


  4 in total

1.  The development of a blend-sampling technique to assess the uniformity of a powder mixture.

Authors:  T P Garcia; S J Wilkinson; J F Scott
Journal:  Drug Dev Ind Pharm       Date:  2001-04       Impact factor: 3.225

2.  Application of a fluorescence sensor for miniscale on-line monitoring of powder mixing kinetics.

Authors:  Chee-Kong Lai; Charles C Cooney
Journal:  J Pharm Sci       Date:  2004-01       Impact factor: 3.534

3.  Nondestructive and on-line monitoring of tablets using light-induced fluorescence technology.

Authors:  Chee Kong Lai; Aina Zahari; Bayen Miller; Wendy E Katstra; Michael J Cima; Charles L Cooney
Journal:  AAPS PharmSciTech       Date:  2004-01-27       Impact factor: 3.246

4.  Comparison of the performance of two sample thieves for the determination of the content uniformity of a powder blend.

Authors:  T P Garcia; M K Taylor; G S Pande
Journal:  Pharm Dev Technol       Date:  1998-02       Impact factor: 3.133

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.