Effect of material selection on the passivity of fit of implant-supported restorations created with computer-aided design/computer-assisted manufacture.

Matthias Karl1, Thomas D Taylor.   

Abstract

PURPOSE: To compare the strain development of conventionally cast three-unit fixed dental prostheses (FDPs) and FDPs fabricated through computer-aided design/computer-assisted manufacture (CAD/CAM) using the strain gauge technique.
MATERIALS AND METHODS: A two-implant situation was transferred to an acrylic resin replica, and strain gauges were attached mesially and distally adjacent to the implants. Seven groups (n = 10) of cement-retained FDPs were manufactured from all restorative materials available for the Etkon CAD/CAM system (Straumann CADCAM). Three groups (n = 10) of conventionally cast screw- and cement-retained superstructures served as controls. Strain development during FDP fixation was recorded, and the logarithm of the absolute strain values was used for statistical analysis (multivariate analysis of variance with Pillai's trace; a = .0033).
RESULTS: Significantly higher strain values for screw-retained FDPs were found than for all other restorations (P < .0000). Conventionally cast cement-retained restorations showed significantly higher strain levels as compared to CAD/CAM restorations fabricated from titanium (P = .0032) and green machined zirconia (P = .0026). Screw-retained superstructures bonded to gold cylinders showed significantly lower strain levels than FDPs made from titanium (P = .0001) and green machined zirconia (P = .0012). No significant differences between the various groups of CAD/CAM restorations could be detected, except that polyamide-resin restorations showed significantly higher strain levels than InCeram Zirconia restorations (P < .0000).
CONCLUSIONS: CAD/CAM-fabricated restorations show fit that is at least as good as that seen for conventionally fabricated superstructures. The choice of restorative material seems to have only a minor effect on the passivity of fit.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21841982

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  3 in total

1.  Effects of Different Surface Treatments on Bond Strength of Resin Cement to Machined Pure Titanium.

Authors:  Yang Cao; Yan-Yang Guo; Lei Chen; Jing Han; Hui Tong; Bao Zhang; Yu Zhang
Journal:  J Adhes Dent       Date:  2019       Impact factor: 2.359

2.  Dimensional Changes of 3-Unit Implant-Supported Zirconia Frameworks of Two CAD/CAM Systems from Scanning to Sintering.

Authors:  Marzieh Alikhasi; Narges Ameri; Hakimeh Siadat; Ahmad Reza Shamshiri; Mohammadreza Nejati
Journal:  Front Dent       Date:  2019-06-29

3.  A strain gauge analysis comparing 4-unit veneered zirconium dioxide implant-borne fixed dental prosthesis on engaging and non-engaging abutments before and after torque application.

Authors:  Alyssa Epprecht; Marco Zeltner; Goran Benic; Mutlu Özcan
Journal:  Clin Exp Dent Res       Date:  2018-02-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.