Literature DB >> 21836402

Comparison of macular thickness measurements between time-domain and spectral-domain optical coherence tomographies in eyes with and without macular abnormalities.

Daniele Giammaria1, Alfonso Ioni, Beatrice Bartoli, Vincenza Cofini, Giacomo Pellegrini, Bruno Giannotti.   

Abstract

PURPOSE: To compare Stratus time-domain optical coherence tomography (OCT) with Cirrus spectral-domain HD-OCT for measuring macular thickness in eyes with and without macular abnormalities.
METHODS: Seventy-five eyes of 48 patients were included in the study. Forty-one eyes of 29 patients had a normal macular thickness, and 34 eyes of 26 patients had an abnormal macular thickness. Macular scans were performed by 2 examiners (E1 and E2) with both OCTs. The agreement between the two OCT systems and interrater repeatability of each OCT system were determined using the Bland-Altman method.
RESULTS: Mean agreement between the 2 OCTs as 1.96 × standard deviation of the mean difference between the measurements of central macular subfield was 21 μm in normal eyes and 36.8 μm in abnormal eyes. In five macular subfields, the agreement was significantly better in normal eyes. Cirrus HD-OCT repeatability was significantly better than Stratus in five macular subfields in normal eyes and in six macular subfields in abnormal eyes. The repeatability was significantly better in normal eyes in five macular subfields for Stratus and in three macular subfields for Cirrus HD-OCT.
CONCLUSION: The agreement between the two OCTs is low and varies in each macular subfield. Cirrus HD-OCT has shown a better repeatability than Stratus OCT, especially when measuring eyes with a thickened macula.

Entities:  

Mesh:

Year:  2011        PMID: 21836402     DOI: 10.1097/IAE.0b013e3181eef401

Source DB:  PubMed          Journal:  Retina        ISSN: 0275-004X            Impact factor:   4.256


  5 in total

1.  Comparison and interchangeability of macular thickness measured with Cirrus OCT and Stratus OCT in myopic eyes.

Authors:  Geng Wang; Kun-Liang Qiu; Xue-Hui Lu; Ming-Zhi Zhang
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

2.  Comparison of choroidal thickness using swept-source and spectral-domain optical coherence tomography in normal Indian eyes.

Authors:  Siddharth Narendran; George Manayath; Narendran Venkatapathy
Journal:  Oman J Ophthalmol       Date:  2018 Jan-Apr

3.  Spectral- and time-domain optical coherence tomography measurements of macular thickness in young myopic eyes.

Authors:  Lin Liu; Jun Zou; Lili Jia; Jian-guo Yang; Shao-rong Chen
Journal:  Diagn Pathol       Date:  2014-02-20       Impact factor: 2.644

4.  Relationship between macular thickness measurement and signal strength using Stratus optical coherence tomography.

Authors:  Ori Segal; Yinon Shapira; Assaf Gershoni; Igor Vainer; Arie Y Nemet; Noa Geffen; Michael Mimouni
Journal:  Clin Ophthalmol       Date:  2016-11-11

Review 5.  Myopia and Regional Variations in Retinal Thickness in Healthy Eyes.

Authors:  Feryal M Zereid; Uchechukwu L Osuagwu
Journal:  J Ophthalmic Vis Res       Date:  2020-04-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.