Literature DB >> 21834924

Changes in vaulting of myopic and toric implantable collamer lenses in different lighting conditions.

Are Lindland1, Hilde Heger, Maria Kugelberg, Charlotta Zetterström.   

Abstract

PURPOSE: To evaluate the changes in vaulting of myopic and toric Implantable Collamer Lenses (ICLs) in different lighting conditions.
METHODS: Thirty-seven eyes of 37 patients implanted with a myopic ICL and 26 eyes of 26 patients implanted with a toric ICL were examined using Visante optical coherence tomography (OCT) in photopic (257 lux) and mesopic (2 lux) conditions. Pupil diameter and distance changes between the ICL and adjacent intraocular structures were measured.
RESULTS: The mean horizontal pupillary diameters in mesopic conditions were 5.3 ± 0.9 (SD) mm. In photopic conditions, a mean decrease of -1.8 ± 0.6 mm [95% confidence interval (95% CI) -2.0 to -1.7; p < 0.0001] was observed. The mean distances between the ICL and the crystalline lens in mesopic conditions were 0.33 ± 0.17 mm. In photopic conditions, a mean decrease of -0.04 ± 0.06 mm (95% CI -0.05 to -0.02; p < 0.0001) in the ICL-crystalline lens distance was found. There was a -0.02 ± 0.04 mm (95% CI -0.03 to -0.01; p = 0.0022) decrease in the anterior chamber depth and a 0.02 ± 0.06 mm (95% CI 0.002 to 0.032; p = 0.0275) increase in the distance between the cornea and the ICL. We found no difference in the change in vaulting between the two ICLs in different lighting conditions.
CONCLUSION: There is a decrease in the central vaulting of myopic and toric ICLs in photopic conditions. This is due to both posterior movement of the ICL and anterior protrusion of the crystalline lens.
© 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

Entities:  

Mesh:

Year:  2011        PMID: 21834924     DOI: 10.1111/j.1755-3768.2011.02224.x

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  8 in total

1.  Inter-Eye Vault Differences of Implantable Collamer Lens Measured Using Anterior Segment Optical Coherence Tomography.

Authors:  Santiago Cerpa Manito; Angel Sánchez Trancón; Oscar Torrado Sierra; António M G Baptista; Pedro Miguel Serra
Journal:  Clin Ophthalmol       Date:  2020-10-29

2.  Effect of Light Conditions and Accommodation on Implantable Phakic Contact Lens Vault by Anterior Segment Optical Coherence Tomography.

Authors:  Mohamed Salah El-Din Mahmoud; Ahmed Shawkat AbdelHalim; Hosny Ahmed Zein
Journal:  Clin Ophthalmol       Date:  2022-05-05

3.  Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation.

Authors:  Qiu-Jian Zhu; Wen-Jing Chen; Wei-Jian Zhu; Hai-Xiang Xiao; Man-Hui Zhu; Lie Ma; You Yuan; E Song
Journal:  BMC Ophthalmol       Date:  2021-05-06       Impact factor: 2.209

4.  Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c).

Authors:  Xun Chen; Huamao Miao; Rajeev Krishnan Naidu; Xiaoying Wang; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2016-09-07       Impact factor: 2.209

5.  Dynamic Assessment of Light-Induced Vaulting Changes of Implantable Collamer Lens With Central Port by Swept-Source OCT: Pilot Study.

Authors:  Felix Gonzalez-Lopez; Blas Mompean; Rafael Bilbao-Calabuig; Jorge Vila-Arteaga; Jaime Beltran; Julio Baviera
Journal:  Transl Vis Sci Technol       Date:  2018-05-01       Impact factor: 3.283

6.  Analysis of pre-operative factors affecting range of optimal vaulting after implantation of 12.6-mm V4c implantable collamer lens in myopic eyes.

Authors:  Hun Lee; David Sung Yong Kang; Jin Young Choi; Byoung Jin Ha; Eung Kweon Kim; Kyoung Yul Seo; Tae-Im Kim
Journal:  BMC Ophthalmol       Date:  2018-07-06       Impact factor: 2.209

7.  Five-year outcomes of EVO implantable collamer lens implantation for the correction of high myopia and super high myopia.

Authors:  Xun Chen; Xuanqi Wang; Yilin Xu; Mingrui Cheng; Tian Han; LingLing Niu; Xiaoying Wang; Xingtao Zhou
Journal:  Eye Vis (Lond)       Date:  2021-11-09

8.  Vault Changes Caused by Light-Induced Pupil Constriction and Accommodation in Eyes With an Implantable Collamer Lens.

Authors:  Sayaka Kato; Kimiya Shimizu; Akihito Igarashi
Journal:  Cornea       Date:  2019-02       Impact factor: 2.651

  8 in total