Literature DB >> 21834706

The accuracy of optical scanning: influence of convergence and die preparation.

D C N Chan1, A K-H Chung, J Haines, E H-T Yau, C-C Kuo.   

Abstract

The purpose of this study was to determine the reliability of the data acquisition and modeling process of laser and white light scanners by evaluating the reproducibility of digitized simulated crowns with different convergences. A secondary purpose was to analyze the influence of die preparation by testing this hypothesis with a set of dies without ditching compared with a set with well-defined margins. Ditching or trimming the die defines the position of the margin and acts as a guide to gingival contour when the restoration is being waxed. Two light scanners (a white light optical scanner [Steinbichler Gmbh, Neubeuern, Germany] and red laser light scanner [TurboDent System, Taichung, Taiwan]) were evaluated. Two sets of simulated crowns were fabricated as cone frustrum models with a total occlusal convergence (TOC) of 0°, 5°, 10°, 15°, 20°, and 25° and a 9-mm base and 3-mm height using a precision milling machine and computer-aided design/computer-aided manufacturing (CAD/CAM) technique. One set of the dies was ditched immediately below the finish line to enhance marginal definition. Each die was optically digitized five times directly with the two different measuring systems. The area of each triangle in the scan that is occlusal to the margin line was calculated and summed to produce the final surface area measurement provided. The digitizing error was compared with the computed surface area of the original master die sets and compared with a paired t-test (df=4; 95% CI). There was no difference in accuracy of the untrimmed dies between the two systems evaluated. We also did not find any difference in the 0° (p=0.12) and 5° degree (p=0.21) groups among the ditched dies. However, when the TOC exceeded 5°, there was a significant difference between the two groups, with the laser groups having a smaller error percentage. Three-dimensional light scanning was not affected by the convergence angle except in the 0°-5° range. Trimming the dies greatly affected the accuracy of scanning.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21834706     DOI: 10.2341/10-067-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  8 in total

Review 1.  Tooth preparation for full-coverage restorations-a literature review.

Authors:  Anke Podhorsky; Peter Rehmann; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2015-03-07       Impact factor: 3.573

2.  In vitro Comparison of the Accuracy (Precision and Trueness) of Seven Dental Scanners.

Authors:  Fariborz Vafaee; Farnaz Firouz; Mahsa Mohajeri; Reza Hashemi; Somayeh Ghorbani Gholiabad
Journal:  J Dent (Shiraz)       Date:  2021-03

3.  Marginal Accuracy and Internal Fit of 3-D Printing Laser-Sintered Co-Cr Alloy Copings.

Authors:  Myung-Joo Kim; Yun-Jung Choi; Seong-Kyun Kim; Seong-Joo Heo; Jai-Young Koak
Journal:  Materials (Basel)       Date:  2017-01-23       Impact factor: 3.623

4.  Efficient digitalization method for dental restorations using micro-CT data.

Authors:  Changhwan Kim; Seung Hoon Baek; Taewon Lee; Jonggun Go; Sun Young Kim; Seungryong Cho
Journal:  Sci Rep       Date:  2017-03-15       Impact factor: 4.379

5.  Influence of intraoral scanning on the quality of preparations for all-ceramic single crowns.

Authors:  Oliver Schubert; Kurt-Jürgen Erdelt; Roland Tittenhofer; Jan Hajtó; Alexander Bergmann; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2020-05-20       Impact factor: 3.573

6.  Fatigue Failure Load of Molars with Thin-Walled Prosthetic Crowns Made of Various Materials: A 3D-FEA Theoretical Study.

Authors:  Noor Al Mortadi; Khaled Bataineh; Mohammad Al Janaideh
Journal:  Clin Cosmet Investig Dent       Date:  2020-12-18

7.  In vitro comparison of the accuracy (precision and trueness) of eight dental scanners for dental bridge scanning.

Authors:  Fariborz Vafaee; Mahsa Mohajeri; Naser Mohammad Gholi Mezerji; Marouf Ebrahim Zadeh
Journal:  Dent Res J (Isfahan)       Date:  2021-10-21

8.  Accuracy of intraoral and extraoral digital data acquisition for dental restorations.

Authors:  Heike Rudolph; Harald Salmen; Matthias Moldan; Katharina Kuhn; Viktor Sichwardt; Bernd Wöstmann; Ralph Gunnar Luthardt
Journal:  J Appl Oral Sci       Date:  2016 Jan-Feb       Impact factor: 2.698

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.