Literature DB >> 21832567

Label-free detection of amyloid growth with microcantilever sensors.

Tuomas P J Knowles1, Wenmiao Shu, François Huber, Hans Peter Lang, Christoph Gerber, Christopher M Dobson, Mark E Welland.   

Abstract

We present an approach for sensing protein aggregation using microcantilever systems. Results from both single cantilever experiments with internal reference and multicantilever array measurements with dedicated reference cantilevers are discussed. We show that in both cases protein aggregation on the sensor can be detected through associated changes in surface stress.

Entities:  

Year:  2008        PMID: 21832567     DOI: 10.1088/0957-4484/19/38/384007

Source DB:  PubMed          Journal:  Nanotechnology        ISSN: 0957-4484            Impact factor:   3.874


  7 in total

1.  Quantitation of pH-induced aggregation in binary protein mixtures by dielectric spectroscopy.

Authors:  Brett L Mellor; Stephen J Wood; Brian A Mazzeo
Journal:  Protein J       Date:  2012-12       Impact factor: 2.371

Review 2.  Approaches to increasing surface stress for improving signal-to-noise ratio of microcantilever sensors.

Authors:  Hai-Feng Ji; Benjamin D Armon
Journal:  Anal Chem       Date:  2010-03-01       Impact factor: 6.986

3.  An analytical model of joule heating in piezoresistive microcantilevers.

Authors:  Mohd Zahid Ansari; Chongdu Cho
Journal:  Sensors (Basel)       Date:  2010-11-01       Impact factor: 3.576

4.  Deflection, frequency, and stress characteristics of rectangular, triangular, and step profile microcantilevers for biosensors.

Authors:  Mohd Zahid Ansari; Chongdu Cho
Journal:  Sensors (Basel)       Date:  2009-07-29       Impact factor: 3.576

5.  A Study on Increasing Sensitivity of Rectangular Microcantilevers Used in Biosensors.

Authors:  Mohd Zahid Ansari; Chongdu Cho
Journal:  Sensors (Basel)       Date:  2008-11-25       Impact factor: 3.576

6.  Study of Alzheimer's Disease-Related Biophysical Kinetics with a Microslit-Embedded Cantilever Sensor in a Liquid Environment.

Authors:  Myung-Sic Chae; Jinsik Kim; Yong Kyoung Yoo; Jeong Hoon Lee; Tae Geun Kim; Kyo Seon Hwang
Journal:  Sensors (Basel)       Date:  2017-08-07       Impact factor: 3.576

7.  Comparison between Deflection and Vibration Characteristics of Rectangular and Trapezoidal profile Microcantilevers.

Authors:  Mohd Zahid Ansari; Chongdu Cho; Jooyong Kim; Booun Bang
Journal:  Sensors (Basel)       Date:  2009-04-16       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.