Literature DB >> 2183121

Complications of sulcus-supported intraocular lenses with iris sutures, implanted during penetrating keratoplasty after intracapsular cataract extraction.

M Busin1, P Brauweiler, T Böker, M Spitznas.   

Abstract

In a retrospective study, the authors analyzed visual results and postoperative complications in a series of 14 consecutive patients who had undergone penetrating keratoplasty and implantation of a posterior chamber intraocular lens (PC IOL) in the absence of the posterior capsule. Seven patients suffered from aphakic bullous keratopathy and seven from pseudophakic bullous keratopathy. Postoperative follow-up was 7.6 months on the average. Best-corrected postoperative visual acuity was 20/60 or better in four cases and 20/200 or better in eight. Glaucoma was present before surgery in four eyes, which persisted in all cases and developed in four new cases. Results of gonioscopic examination showed the postoperative development of goniosynechiae in four eyes. Pseudophakodonesis of various extent was present in ten eyes. Preoperatively, cystoid macular edema was diagnosed angiographically in one case. It did not improve after surgery and was seen in three additional eyes postoperatively. Causes for postoperative visual acuity lower than 20/200 were cystoid macular edema in three cases, graft rejection in one case, central retinal scar in one case, and optic nerve atrophy in one case. A distortion of the pupil was seen in three eyes in miosis and in four additional eyes in mydriasis. Corneal thickness as well as anterior chamber depth were within normal limits. Fluorophotometric evaluation of the blood-aqueous barrier showed values comparable with those obtained after intracapsular cataract extraction and implantation of an iris-fixated IOL. Despite the relatively good visual results, the high postoperative incidence of cystoid macular edema and/or glaucoma may discourage the use of this technique.

Entities:  

Mesh:

Year:  1990        PMID: 2183121     DOI: 10.1016/s0161-6420(90)32570-8

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  4 in total

1.  Combined penetrating keratoplasty and posterior chamber intraocular lens implantation in the absence of a lens capsule.

Authors:  R N Gaster; R C Troutman; H V Ong; A Draga; S C Belmont
Journal:  Trans Am Ophthalmol Soc       Date:  1990

2.  Penetrating keratoplasty for pseudophakic corneal oedema.

Authors:  J Kwartz; B Leatherbarrow; P Dyer; A E Ridgway; A B Tullo
Journal:  Br J Ophthalmol       Date:  1995-05       Impact factor: 4.638

3.  Corneal astigmatism correction with scleral flaps in trans-scleral suture-fixed posterior chamber lens implantation: a preliminary clinical observation.

Authors:  Li-Wei Ma; Dwight Xuan; Xiao-Yan Li; Jin-Song Zhang
Journal:  Int J Ophthalmol       Date:  2011-10-18       Impact factor: 1.779

4.  Experience with transscleral fixation of posterior chamber lenses.

Authors:  R Sundmacher; C Althaus; R Wester
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.