OBJECTIVE: To determine test-retest and inter-rater reliability of hand-held dynamometry when used to measure knee--extensor strength in patients with advanced cancer. SUBJECTS: Adults with metastatic or locally advanced cancer recruited from palliative care services to a study of the risk factors for falls. METHODS: Consecutive recruits (n = 30) underwent repeat testing after an interval of 1 h, by the same researcher, to assess test-retest reliability. The subsequent 15 patients underwent retesting by a second researcher. The intra-class correlation coefficient and limits of agreement were calculated. RESULTS: The test-retest reliability difference between measurements increased with the magnitude of measurement, mean leg strength = 113 N (standard deviation 43.1), 95% ratio limits of agreement 0.81-1.5, intra-class correlation coefficient = 0.9. The inter-rater testing mean leg strength = 128.5 N (standard deviation 35.1), 95% limits of agreement = -57.24 to 36.06 N. Intra-class correlation coefficient = 0.83. CONCLUSION: Test-retesting and inter-rater testing yielded high intra-class correlation coefficients, but the limits of agreement were wide. In test-retesting, the difference between tests increased as the magnitude of measurement increased. It has been widely reported that hand-held dynamometry is reliable when used to measure knee-extensor strength in frail or elderly persons. However, our results show that, even in these populations, reliability may be compromised by inadequate tester strength.
OBJECTIVE: To determine test-retest and inter-rater reliability of hand-held dynamometry when used to measure knee--extensor strength in patients with advanced cancer. SUBJECTS: Adults with metastatic or locally advanced cancer recruited from palliative care services to a study of the risk factors for falls. METHODS: Consecutive recruits (n = 30) underwent repeat testing after an interval of 1 h, by the same researcher, to assess test-retest reliability. The subsequent 15 patients underwent retesting by a second researcher. The intra-class correlation coefficient and limits of agreement were calculated. RESULTS: The test-retest reliability difference between measurements increased with the magnitude of measurement, mean leg strength = 113 N (standard deviation 43.1), 95% ratio limits of agreement 0.81-1.5, intra-class correlation coefficient = 0.9. The inter-rater testing mean leg strength = 128.5 N (standard deviation 35.1), 95% limits of agreement = -57.24 to 36.06 N. Intra-class correlation coefficient = 0.83. CONCLUSION: Test-retesting and inter-rater testing yielded high intra-class correlation coefficients, but the limits of agreement were wide. In test-retesting, the difference between tests increased as the magnitude of measurement increased. It has been widely reported that hand-held dynamometry is reliable when used to measure knee-extensor strength in frail or elderly persons. However, our results show that, even in these populations, reliability may be compromised by inadequate tester strength.
Authors: Bader A Alqahtani; Mary Ann Ferchak; Theodore J Huppert; Ervin Sejdic; Subashan Perera; Susan L Greenspan; Patrick J Sparto Journal: Aging Clin Exp Res Date: 2016-12-20 Impact factor: 3.636
Authors: François Maltais; Marc Decramer; Richard Casaburi; Esther Barreiro; Yan Burelle; Richard Debigaré; P N Richard Dekhuijzen; Frits Franssen; Ghislaine Gayan-Ramirez; Joaquim Gea; Harry R Gosker; Rik Gosselink; Maurice Hayot; Sabah N A Hussain; Wim Janssens; Micheal I Polkey; Josep Roca; Didier Saey; Annemie M W J Schols; Martijn A Spruit; Michael Steiner; Tanja Taivassalo; Thierry Troosters; Ioannis Vogiatzis; Peter D Wagner Journal: Am J Respir Crit Care Med Date: 2014-05-01 Impact factor: 21.405
Authors: Pierrette Baschung Pfister; Eling D de Bruin; Iris Sterkele; Britta Maurer; Rob A de Bie; Ruud H Knols Journal: PLoS One Date: 2018-03-29 Impact factor: 3.240