Literature DB >> 21825183

Outcome of toric intraocular lens implantation after adjusting for anterior chamber depth and intraocular lens sphere equivalent power effects.

Michael Goggin1, Sacha Moore, Adrian Esterman.   

Abstract

OBJECTIVE: To describe the refractive outcome of toric intraocular lens (IOL) implantation by taking into account the effect on astigmatic outcome of the anterior chamber depth and the sphere power of the IOL, and to examine whether the predictability of the toric effect can be improved.
METHOD: In a university department in a publicly funded hospital, 38 eyes of 29 patients underwent routine cataract surgery with insertion of a toric implant (SN60TT AcrySof Toric). The corneal plane effective cylinder power of the IOL was calculated, including the effect on this value of the anterior chamber depth and pachymetry and of the sphere power of the IOL.
RESULTS: The mean (SD) corneal plane equivalent cylinder power of the IOL predicted preoperatively by the manufacturer as 1.58 (0.47) diopters (D) vs 2.02 (0.64) D by us (calculated using predicted postoperative anterior chamber depth and IOL sphere values). The mean (SD) measured postoperative value was 1.78 (0.89) D, which was better predicted by us.
CONCLUSIONS: The manufacturer currently appears to underestimate the corneal plane effective cylinder power of its toric IOLs. Improved outcome could be achieved by estimating the effective corneal plane cylinder power of the IOL, as altered by the anterior chamber depth and pachymetry and by the IOL sphere power, but this is currently not addressed by the manufacturer.

Entities:  

Mesh:

Year:  2011        PMID: 21825183     DOI: 10.1001/archophthalmol.2011.188

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  10 in total

1.  A one-point technique for per-operative corneal meridian identification: corneal marking technique.

Authors:  Shane R Durkin; Michael Goggin
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-05-29       Impact factor: 3.117

2.  Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position.

Authors:  Youngsub Eom; Dongok Ryu; Dae Wook Kim; Seul Ki Yang; Jong Suk Song; Sug-Whan Kim; Hyo Myung Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-08-19       Impact factor: 3.117

3.  Comparison of surgically induced astigmatism between one-handed and two-handed cataract surgery techniques.

Authors:  Asushi Kawahara; Daijiro Kurosaka; Aktoshi Yoshida
Journal:  Clin Ophthalmol       Date:  2013-10-02

4.  Comparison of the clinical outcomes of Eyecryl and Tecnis® toric intraocular lenses: A real-world study.

Authors:  Mithun Thulasidas; Ajita Sasidharan; Balam Pradeep
Journal:  Indian J Ophthalmol       Date:  2022-03       Impact factor: 2.969

5.  Comparison of the Astigmatic Power of Toric Intraocular Lenses Using Three Toric Calculators.

Authors:  Hyun Ju Park; Hun Lee; Young Jae Woo; Eung Kweon Kim; Kyoung Yul Seo; Ha Yan Kim; Tae-im Kim
Journal:  Yonsei Med J       Date:  2015-07       Impact factor: 2.759

6.  Vector analysis investigation of toric intraocular lens with no deviation from the intended axis.

Authors:  Atsushi Kawahara; Yoshinori Takayanagi
Journal:  Clin Ophthalmol       Date:  2016-11-02

Review 7.  Toric intraocular lenses: Evidence-based use.

Authors:  Michael Goggin
Journal:  Clin Exp Ophthalmol       Date:  2022-05-29       Impact factor: 4.383

8.  A Direct Method for Determining Toricity Ratios of Toric Intraocular Lens Calculators.

Authors:  Lauren G Gabra; Samir I Sayegh
Journal:  Sci Rep       Date:  2018-03-15       Impact factor: 4.379

9.  Comparison of the clinical efficacy of AcrySof® IQ and TECNIS® toric intraocular lenses: A real-world study.

Authors:  Juan-Juan Yang; Ya-Zhou Qin; Li Qin; Jing-Ming Li
Journal:  Exp Ther Med       Date:  2020-08-28       Impact factor: 2.447

10.  Clinical Outcomes of Toric Intraocular Lenses: Differences in Expected Outcomes When Using a Calculator That Considers Effective Lens Position and the Posterior Cornea vs One That Does Not.

Authors:  Elizabeth Yeu; Albert Y Cheung; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2020-03-16
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.