Literature DB >> 21824704

Mandible reconstruction assisted by preoperative simulation and transferring templates: cadaveric study of accuracy.

Guang-sen Zheng1, Yu-xiong Su, Gui-qing Liao, Pei-feng Jiao, Li-zhong Liang, Si-en Zhang, Hai-chao Liu.   

Abstract

PURPOSE: In this study we tried to define tumor resection, fibula cutting, and positioning by surgical templates to perform the mandible reconstruction surgery according to the preoperative simulation. The accuracy was evaluated through cadaveric surgery.
MATERIALS AND METHODS: Five cadaveric mandibles and fibulas were obtained. Preoperative surgical simulation was performed. Surgical templates that defined tumor resection, fibula cutting, and positioning were designed and fabricated. Translation, angular deviation, and rotation of bone grafts, as well as translation of condyles, were measured.
RESULTS: The reconstructed mandibles showed high similarity to the surgical planning. The mean translation, angular deviation, and rotation of fibula segments of the reconstructed mandibles were 1.35 ± 0.86 mm, 3.36° ± 1.86°, and 8.13° ± 5.35°, respectively. In the mandible remnants, the translation of condyles was measured, with a mean of 1.39 ± 0.66 mm.
CONCLUSIONS: Our method of defining the tumor resection, fibula cutting, and positioning by surgical templates was accurate enough for mandible reconstruction surgery.
Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21824704     DOI: 10.1016/j.joms.2011.05.015

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  8 in total

1.  Navigation Guidance During Free Flap Mandibular Reconstruction: A Cadaveric Trial.

Authors:  R Alex Harbison; Xiao-Feng Shan; Zachary Douglas; Scott Bevans; Yangming Li; Kris S Moe; Neal Futran; Jeffrey J Houlton
Journal:  JAMA Otolaryngol Head Neck Surg       Date:  2017-03-01       Impact factor: 6.223

2.  Patient-tailored plate for bone fixation and accurate 3D positioning in corrective osteotomy.

Authors:  J G G Dobbe; J C Vroemen; S D Strackee; G J Streekstra
Journal:  Med Biol Eng Comput       Date:  2012-10-10       Impact factor: 2.602

3.  Considerations and Protocols in Virtual Surgical Planning of Reconstructive Surgery for More Accurate and Esthetic Neomandible with Deep Circumflex Iliac Artery Free Flap.

Authors:  Nam-Kyoo Kim; Hyun Young Kim; Hyung Jun Kim; In-Ho Cha; Woong Nam
Journal:  Maxillofac Plast Reconstr Surg       Date:  2014-07-30

4.  Low-cost Design and Manufacturing of Surgical Guides for Mandibular Reconstruction Using a Fibula.

Authors:  Toshiaki Numajiri; Hiroko Nakamura; Yoshihiro Sowa; Kenichi Nishino
Journal:  Plast Reconstr Surg Glob Open       Date:  2016-07-15

5.  New frontiers and emerging applications of 3D printing in ENT surgery: a systematic review of the literature.

Authors:  P Canzi; M Magnetto; S Marconi; P Morbini; S Mauramati; F Aprile; I Avato; F Auricchio; M Benazzo
Journal:  Acta Otorhinolaryngol Ital       Date:  2018-08       Impact factor: 2.124

6.  Three-Dimensionally Printed Patient-Specific Surgical Plates Increase Accuracy of Oncologic Head and Neck Reconstruction Versus Conventional Surgical Plates: A Comparative Study.

Authors:  Wei-Fa Yang; Wing Shan Choi; May Chun-Mei Wong; Warit Powcharoen; Wang-Yong Zhu; James Kit-Hon Tsoi; Marco Chow; Ka-Wai Kwok; Yu-Xiong Su
Journal:  Ann Surg Oncol       Date:  2020-06-22       Impact factor: 5.344

7.  Preliminary clinic study on computer assisted mandibular reconstruction: the positive role of surgical navigation technique.

Authors:  Jin-Wei Huang; Xiao-Feng Shan; Xu-Guang Lu; Zhi-Gang Cai
Journal:  Maxillofac Plast Reconstr Surg       Date:  2015-07-30

8.  Precision of fibula positioning guide in mandibular reconstruction with a fibula graft.

Authors:  Se-Ho Lim; Moon-Key Kim; Sang-Hoon Kang
Journal:  Head Face Med       Date:  2016-01-27       Impact factor: 2.151

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.