Literature DB >> 21823375

Comparison of cardiac output measurements in critically ill patients: FloTrac/Vigileo vs transthoracic Doppler echocardiography.

A S McLean1, S J Huang, M Kot, A Rajamani, L Hoyling.   

Abstract

Measurement of cardiac output is an integral part of patient management in the intensive care unit. FloTrac/Vigileo is a continuous cardiac output monitoring device that does not need re-calibration. However its reliability has been questioned in some studies, especially involving surgical patients. In this study, we evaluated the comparability of FloTrac/Vigileo and transthoracic Doppler echocardiography in 53 critically ill patients requiring continuous cardiac output monitoring. Most of these patients had septic or cardiogenic shock. Cardiac output was measured by both FloTrac/Vigileo and transthoracic Doppler echocardiography. The bias and precision (mean and SD) between the two devices was 0.35 +/- 1.35 l/minute. The limits of agreement were -2.3 to 3.0 l/minute (%error = 49.3%). When patients with irregular heart rhythms and aortic stenosis were excluded, the bias and precision was 0.02 +/- 0.80 l/minute (n = 42). The limits of agreement were -1.55 to 1.59 l/minute (%error = 29.5%). Patient demographics (body surface area, gender and age) did not affect the bias, but there was a mild tendency for FloTrac/ Vigileo to register a higher cardiac output at high heart rates. Changes in cardiac output for two consecutive days correlated well between the two methods (r = 0.86; P < 0.001). In summary, with the exceptions of patients with irregular heart rhythms and significant aortic stenosis, FloTrac/Vigileo is clinically comparable to transthoracic Doppler echocardiography in cardiac output measurements in critically ill patients.

Entities:  

Mesh:

Year:  2011        PMID: 21823375     DOI: 10.1177/0310057X1103900409

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  8 in total

1.  Applications of minimally invasive cardiac output monitors.

Authors:  Jahan Porhomayon; Gino Zadeii; Samuel Congello; Nader D Nader
Journal:  Int J Emerg Med       Date:  2012-04-24

2.  The Japanese guidelines for the management of sepsis.

Authors:  Shigeto Oda; Mayuki Aibiki; Toshiaki Ikeda; Hitoshi Imaizumi; Shigeatsu Endo; Ryoichi Ochiai; Joji Kotani; Nobuaki Shime; Osamu Nishida; Takayuki Noguchi; Naoyuki Matsuda; Hiroyuki Hirasawa
Journal:  J Intensive Care       Date:  2014-10-28

3.  Perioperative fluid guidance with transthoracic echocardiography and pulse-contour device in morbidly obese patients.

Authors:  Tomi Pösö; Ola Winsö; Roman Aroch; Doris Kesek
Journal:  Obes Surg       Date:  2014-12       Impact factor: 4.129

4.  Early interventional therapy for acute massive pulmonary embolism guided by minimally invasive hemodynamic monitoring.

Authors:  Lihua Wang; Yi Xu; Weiwen Zhang; Wei Lu; Meiqin Chen; Jian Luo
Journal:  Int J Clin Exp Med       Date:  2015-08-15

5.  Correlation of Stroke Volume Measurement between Sonosite Portable Echocardiogram and Edwards Flotrac Sensor-Vigileo Monitor in an Intensive Care Unit.

Authors:  Mehrdad Behnia; Sherry Powell; Linda Fallen; Houman Tamaddon; Masud Behnia
Journal:  Clin Med Insights Circ Respir Pulm Med       Date:  2013-09-08

6.  Feasibility of biventricular 3D transthoracic echocardiography in the critically ill and comparison with conventional parameters.

Authors:  Sam Orde; Michel Slama; Nicola Stanley; Stephen Huang; Anthony Mclean
Journal:  Crit Care       Date:  2018-08-19       Impact factor: 9.097

7.  Comparison of pulmonary artery catheter, echocardiography, and arterial waveform analysis monitoring in predicting the hemodynamic state during and after cardiac surgery.

Authors:  Paul Power; Allison Bone; Nicholas Simpson; Cheng-Hon Yap; Simon Gower; Michael Bailey
Journal:  Int J Crit Illn Inj Sci       Date:  2017 Jul-Sep

8.  Comment on the Edwards FloTrac/Vigileo versus pulmonary artery catheter study: What is really going on with this patient?

Authors:  Alex Botsch; Michael S Firstenberg
Journal:  Int J Crit Illn Inj Sci       Date:  2017 Jul-Sep
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.