Literature DB >> 2182164

Coronary arteriography in a district general hospital: feasibility, safety, and diagnostic accuracy.

K Ranjadayalan1, P G Mills, D C Sprigings, K Mourad, P Magee, A D Timmis.   

Abstract

OBJECTIVE: To determine the feasibility, safety, and diagnostic accuracy of coronary arteriography in the radiology department of a district general hospital using conventional fluoroscopy and videotape recording.
DESIGN: Observational study of the feasibility and safety of coronary arteriography in a district general hospital and analysis of its diagnostic accuracy by prospective within patient comparison of the video recordings with cinearteriograms obtained in a catheter laboratory.
SETTING: Radiology department of a district general hospital and the catheter laboratory of a cardiological referral centre.
SUBJECTS: 50 Patients with acute myocardial infarction treated with streptokinase who underwent coronary arteriography in a district general hospital three (two to five) days after admission. 45 Of these patients had repeat coronary arteriography after four (three to seven) days in the catheter laboratory of a cardiological referral centre. MAIN OUTCOME MEASURES: Incidence of complications associated with catheterisation and the sensitivity and specificity of video recordings in the district general hospital (judged by two experienced observers) for identifying the location and severity of coronary stenoses.
RESULTS: Coronary arteriograms recorded on videotape in the district general hospital were obtained in 47 cases and apart from one episode of ventricular fibrilation (treated successfully by cardioversion) there were no complications of the procedure. 45 Patients were transferred for investigation in the catheter laboratory, providing 45 paired coronary arteriograms recorded on videotape and cine film. The specificity of the video recordings for identifying the location and severity of coronary stenoses was over 90%. Sensitivity, however, was lower and for one observer fell below 40% for lesions in the circumflex artery. A cardiothoracic surgeon judged that only nine of the 47 video recordings were adequate for assessing revascularisation requirements.
CONCLUSIONS: Coronary arteriography in the radiology department of a district general hospital is safe and feasible. Nevertheless, the quality of image with conventional fluoroscopy and video film is inadequate and will need to be improved before coronary arteriography in this setting can be recommended.

Entities:  

Mesh:

Year:  1990        PMID: 2182164      PMCID: PMC1662551          DOI: 10.1136/bmj.300.6727.777

Source DB:  PubMed          Journal:  BMJ        ISSN: 0959-8138


  8 in total

1.  Pulmonary shunting after cardiopulmonary bypass.

Authors:  H H Korsten; J A Leusink; J Spierdijk; J H Meijer; J E Beneken; W G Zijlstra
Journal:  Eur Heart J       Date:  1989-12       Impact factor: 29.983

2.  Automated quantitative coronary arteriography: morphologic and physiologic validation in vivo of a rapid digital angiographic method.

Authors:  G B Mancini; S B Simon; M J McGillem; M T LeFree; H Z Friedman; R A Vogel
Journal:  Circulation       Date:  1987-02       Impact factor: 29.690

3.  Complications of coronary arteriography from the Collaborative Study of Coronary Artery Surgery (CASS).

Authors:  K Davis; J W Kennedy; H G Kemp; M P Judkins; A J Gosselin; T Killip
Journal:  Circulation       Date:  1979-06       Impact factor: 29.690

4.  Intracoronary thrombolytic therapy performed within a coronary care unit: one year's experience.

Authors:  W S Hillis; C R Jones; M Been; B C Campbell; W F Fulton
Journal:  Scott Med J       Date:  1986-01       Impact factor: 0.729

5.  Complications associated with cardiac catheterization and angiography.

Authors:  J W Kennedy
Journal:  Cathet Cardiovasc Diagn       Date:  1982

6.  Digital subtraction angiographic imaging of coronary flow reserve.

Authors:  J T Cusma; E J Toggart; J D Folts; W W Peppler; N J Hangiandreou; C S Lee; C A Mistretta
Journal:  Circulation       Date:  1987-02       Impact factor: 29.690

7.  Anisoylated plasminogen streptokinase activator complex in acute myocardial infarction: a placebo-controlled arteriographic coronary recanalization study.

Authors:  A D Timmis; B Griffin; J C Crick; E Sowton
Journal:  J Am Coll Cardiol       Date:  1987-07       Impact factor: 24.094

8.  Mortality related to cardiac catheterization and angiography.

Authors:  J W Kennedy; W A Baxley; I L Bunnel; G G Gensini; J V Messer; J G Mudd; T J Noto; S Paulin; A D Pichard; W C Sheldon; M Cohen
Journal:  Cathet Cardiovasc Diagn       Date:  1982
  8 in total
  2 in total

1.  Diagnostic cardiac catheterisation in a hospital without on-site cardiac surgery.

Authors:  H D Papaconstantinou; A J Marshall; C J Burrell
Journal:  Heart       Date:  1999-05       Impact factor: 5.994

2.  Limitations in the use of five French coronary catheters.

Authors:  E F Brown; G G Hartnell; K Morris; P Wilde
Journal:  Int J Card Imaging       Date:  1991
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.