Literature DB >> 21821351

The lognormal perfusion model for disruption replenishment measurements of blood flow: in vivo validation.

John M Hudson1, Kogee Leung, Peter N Burns.   

Abstract

Dynamic contrast enhanced ultrasound (DCE-US) is evolving as a promising tool to noninvasively quantify relative tissue perfusion in organs and solid tumours. Quantification using the method of disruption replenishment is best performed using a model that accurately describes the replenishment of microbubble contrast agents through the ultrasound imaging plane. In this study, the lognormal perfusion model was validated using an exposed in vivo rabbit kidney model. Compared against an implanted transit time flow meter, longitudinal relative flow measurement was (×3) less variable and correlated better when quantification was performed with the lognormal perfusion model (Spearman r = 0.90, 95% confidence interval [CI] = 0.05) vs. the prevailing mono-exponential model (Spearman r = 0.54, 95% CI = 0.18). Disruption-replenishment measurements using the lognormal perfusion model were reproducible in vivo to within 12%.
Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21821351     DOI: 10.1016/j.ultrasmedbio.2011.06.009

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  6 in total

1.  Intra-Animal Comparison between Three-dimensional Molecularly Targeted US and Three-dimensional Dynamic Contrast-enhanced US for Early Antiangiogenic Treatment Assessment in Colon Cancer.

Authors:  Huaijun Wang; Amelie M Lutz; Dimitre Hristov; Lu Tian; Jürgen K Willmann
Journal:  Radiology       Date:  2016-08-04       Impact factor: 11.105

2.  Interobserver Variation of the Bolus-and-Burst Method for Pancreatic Perfusion with Dynamic - Contrast-Enhanced Ultrasound.

Authors:  Marcus Stangeland; Trond Engjom; Martin Mezl; Radovan Jirik; Odd Helge Gilja; Georg Dimcevski; Kim Nylund
Journal:  Ultrasound Int Open       Date:  2017-09-12

3.  Effects of high-fat diet and losartan on renal cortical blood flow using contrast ultrasound imaging.

Authors:  Anne-Emilie Declèves; Joshua J Rychak; Dan J Smith; Kumar Sharma
Journal:  Am J Physiol Renal Physiol       Date:  2013-09-18

4.  Reducing tumor growth and angiogenesis using a triple therapy measured with Contrast-enhanced ultrasound (CEUS).

Authors:  Philipp Marius Paprottka; Svenja Roßpunt; Michael Ingrisch; Clemens C Cyran; Konstantin Nikolaou; Maximilian F Reiser; Brigitte Mack; Olivier Gires; Dirk A Clevert; Pamela Zengel
Journal:  BMC Cancer       Date:  2015-05-08       Impact factor: 4.430

5.  Quantitative Three-Dimensional Dynamic Contrast-Enhanced Ultrasound Imaging: First-In-Human Pilot Study in Patients with Liver Metastases.

Authors:  Ahmed El Kaffas; Rosa Maria Silveira Sigrist; George Fisher; Sunitha Bachawal; Joy Liau; Huaijun Wang; Alexander Karanany; Isabelle Durot; Jarrett Rosenberg; Dimitre Hristov; Jürgen K Willmann
Journal:  Theranostics       Date:  2017-08-23       Impact factor: 11.556

6.  Spatial Characterization of Tumor Perfusion Properties from 3D DCE-US Perfusion Maps are Early Predictors of Cancer Treatment Response.

Authors:  Ahmed El Kaffas; Assaf Hoogi; Jianhua Zhou; Isabelle Durot; Huaijun Wang; Jarrett Rosenberg; Albert Tseng; Hersh Sagreiya; Alireza Akhbardeh; Daniel L Rubin; Aya Kamaya; Dimitre Hristov; Jürgen K Willmann
Journal:  Sci Rep       Date:  2020-04-24       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.