Literature DB >> 21819705

Comparison of the predictability, uniformity and stability of a laser in situ keratomileusis corneal flap created with a VisuMax femtosecond laser or a Moria microkeratome.

P Yao1, Y Xu, X Zhou.   

Abstract

This prospective study compared the predictability, uniformity and stability of laser in situ keratomileusis corneal flap thickness created by a femtosecond laser or a classic microkeratome. Twenty-five femtosecond laser (VisuMax, Carl Zeiss Meditec) flaps and 38 microkeratome (Moria M3) flaps were measured using anterior segment optical coherence tomography at 1 week, 1 month and 6 months postoperatively. Flap thickness at seven points on each of the four meridians was calculated. At 6 months, VisuMax flaps showed better prediction than Moria flaps for central flap thickness. The standard deviation within individual flaps was smaller for VisuMax flaps and their index of symmetry was better. The mean thicknesses among the four eccentricities in the VisuMax flaps were the same, while Moria flaps were thicker at the 3-mm radius compared with the centre. The VisuMax femtosecond laser created corneal flaps with better predictability and uniformity, and similar reproducibility and stability, compared with the microkeratome.

Entities:  

Mesh:

Year:  2011        PMID: 21819705     DOI: 10.1177/147323001103900306

Source DB:  PubMed          Journal:  J Int Med Res        ISSN: 0300-0605            Impact factor:   1.671


  7 in total

1.  Artemis very high frequency digital ultrasound-guided femtosecond laser recut after flap complication.

Authors:  Dan Z Reinstein; Zachary Dickeson; Timothy J Archer; Marine Gobbe
Journal:  Digit J Ophthalmol       Date:  2014-09-14

2.  Very late-onset flap margin corneal ulcer following laser in situ keratomileusis.

Authors:  Gilad Rabina; Nur Azem; Michael Mimouni; Idan Hecht; David Varssano
Journal:  Int Ophthalmol       Date:  2019-04-13       Impact factor: 2.031

3.  Evaluation of morphological features: femtosecond-LASIK flap vs. SMILE cap, and the effects on corneal higher-order aberrations.

Authors:  Xiaoying He; Qin He; Minjie Yuan; Zhi Fang; Kai Zhang; Tiepei Zhu; Wei Han
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-09-27       Impact factor: 3.535

4.  Visumax femtolasik versus Moria M2 microkeratome in mild to moderate myopia: efficacy, safety, predictability, aberrometric changes and flap thickness predictability.

Authors:  Magda A Torky; Yousif A Al Zafiri; Abeer M Khattab; Rania K Farag; Eman A Awad
Journal:  BMC Ophthalmol       Date:  2017-07-17       Impact factor: 2.209

5.  Redo surgery using IntraLase femtosecond laser for treating a decentered laser in situ keratomileusis flap.

Authors:  Yulin Lei; Jie Hou; Xiuyun Zheng
Journal:  J Int Med Res       Date:  2017-09-06       Impact factor: 1.671

Review 6.  Small incision lenticule extraction (SMILE) history, fundamentals of a new refractive surgery technique and clinical outcomes.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe
Journal:  Eye Vis (Lond)       Date:  2014-10-16

7.  The morphology of corneal cap and its relation to refractive outcomes in femtosecond laser small incision lenticule extraction (SMILE) with anterior segment optical coherence tomography observation.

Authors:  Jing Zhao; Peijun Yao; Meiyan Li; Zhi Chen; Yang Shen; Zhennan Zhao; Zimei Zhou; Xingtao Zhou
Journal:  PLoS One       Date:  2013-08-05       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.