Literature DB >> 21818532

A single camera photogrammetry system for multi-angle fast localization of EEG electrodes.

Shuo Qian1, Yang Sheng.   

Abstract

Photogrammetry has become an effective method for the determination of electroencephalography (EEG) electrode positions in three dimensions (3D). Capturing multi-angle images of the electrodes on the head is a fundamental objective in the design of photogrammetry system for EEG localization. Methods in previous studies are all based on the use of either a rotating camera or multiple cameras, which are time-consuming or not cost-effective. This study aims to present a novel photogrammetry system that can realize simultaneous acquisition of multi-angle head images in a single camera position. Aligning two planar mirrors with the angle of 51.4°, seven views of the head with 25 electrodes are captured simultaneously by the digital camera placed in front of them. A complete set of algorithms for electrode recognition, matching, and 3D reconstruction is developed. It is found that the elapsed time of the whole localization procedure is about 3 min, and camera calibration computation takes about 1 min, after the measurement of calibration points. The positioning accuracy with the maximum error of 1.19 mm is acceptable. Experimental results demonstrate that the proposed system provides a fast and cost-effective method for the EEG positioning.

Mesh:

Year:  2011        PMID: 21818532     DOI: 10.1007/s10439-011-0374-6

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  5 in total

1.  Smartphone-based photogrammetry provides improved localization and registration of scalp-mounted neuroimaging sensors.

Authors:  Ilaria Mazzonetto; Marco Castellaro; Robert J Cooper; Sabrina Brigadoi
Journal:  Sci Rep       Date:  2022-06-27       Impact factor: 4.996

2.  Accuracy of high-density EEG electrode position measurement using an optical scanner compared with the photogrammetry method.

Authors:  Orsolya Györfi; Cheng-Teng Ip; Anders Bach Justesen; Maria Louise Gam-Jensen; Connie Rømer; Martin Fabricius; Lars H Pinborg; Sándor Beniczky
Journal:  Clin Neurophysiol Pract       Date:  2022-05-02

3.  Photogrammetry-Based Head Digitization for Rapid and Accurate Localization of EEG Electrodes and MEG Fiducial Markers Using a Single Digital SLR Camera.

Authors:  Tommy Clausner; Sarang S Dalal; Maité Crespo-García
Journal:  Front Neurosci       Date:  2017-05-16       Impact factor: 4.677

4.  Optical Co-registration of MRI and On-scalp MEG.

Authors:  Rasmus Zetter; Joonas Iivanainen; Lauri Parkkonen
Journal:  Sci Rep       Date:  2019-04-02       Impact factor: 4.379

5.  Multimodal spatial calibration for accurately registering EEG sensor positions.

Authors:  Jianhua Zhang; Jian Chen; Shengyong Chen; Gang Xiao; Xiaoli Li
Journal:  Comput Math Methods Med       Date:  2014-04-03       Impact factor: 2.238

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.