Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisation.

Graciano Paulo1, Joana Santos, Ana Moreira, Filipa Figueiredo.   

Abstract

In paediatrics, the risks associated with ionising radiation should be a major concern, due to children's higher susceptibility to radiation effects. Measure entrance skin dose (ESD) in chest and pelvis X-ray projections and compare the results with the 'European guidelines on quality criteria for diagnostic radiographer images in paediatrics' in order to optimise radiological practice. ESD values were obtained using an ionisation chamber Diamentor M4 KDK (PTW) in 429 children, who underwent chest X-ray or pelvis X-ray in a Computed Radiography system. In the first phase of the study, data were collected according to protocols used in the department; in a second phase different tube voltage values were used according to patient weight. A third phase was carried out, only for chest X-ray, using the exposure parameters of phase 2, plus activating lateral ionisation chamber. Three paediatric radiologists blindly assessed image quality of chest X-ray, using a validated assessment available in the 'European guidelines on quality criteria for diagnostic radiographer images in paediatrics'. Considering all the patients submitted to chest X-ray, the average ESD was 0.22, 0.16 and 0.08 mGy, for phases 1, 2 and 3, respectively. For pelvis X-ray, the average ESD decreased from 1.18 mGy in phase 1 to 0.78 mGy in phase 2. Dose optimisation was achieved. ESD was reduced 63.6 and 33.9 % in chest and pelvis X-ray, respectively.

Entities:  

Mesh:

Year:  2011        PMID: 21816730     DOI: 10.1093/rpd/ncr355

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  2 in total

1.  Radiation dose optimisation for conventional imaging in infants and newborns using automatic dose management software: an application of the new 2013/59 EURATOM directive.

Authors:  L Alejo; E Corredoira; F Sánchez-Muñoz; C Huerga; Z Aza; R Plaza-Núñez; A Serrada; M Bret-Zurita; M Parrón; C Prieto-Areyano; G Garzón-Moll; R Madero; E Guibelalde
Journal:  Br J Radiol       Date:  2018-04-09       Impact factor: 3.039

2.  Optimisation of tube voltage range (kVp) for AP abdomen, pelvis and spine imaging of average patients with a digital radiography (DR) imaging system using a computer simulator.

Authors:  Craig Steven Moore; Tim Wood; Stephen Balcam; Liam Needler; Tim Guest; Wee Ping Ngu; Lee Wun Chong; John Saunderson; Andrew Beavis
Journal:  Br J Radiol       Date:  2020-08-12       Impact factor: 3.039

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.