Literature DB >> 21815935

Distribution of exhaled contaminants and personal exposure in a room using three different air distribution strategies.

I Olmedo1, P V Nielsen, M Ruiz de Adana, R L Jensen, P Grzelecki.   

Abstract

UNLABELLED: The level of exposure to human exhaled contaminants in a room depends not only on the air distribution system but also on people's different positions, the distance between them, people's activity level and height, direction of exhalation, and the surrounding temperature and temperature gradient. Human exhalation is studied in detail for different distribution systems: displacement and mixing ventilation as well as a system without mechanical ventilation. Two thermal manikins breathing through the mouth are used to simulate the exposure to human exhaled contaminants. The position and distance between the manikins are changed to study the influence on the level of exposure. The results show that the air exhaled by a manikin flows a longer distance with a higher concentration in case of displacement ventilation than in the other two cases, indicating a significant exposure to the contaminants for one person positioned in front of another. However, in all three cases, the exhalation flow of the source penetrates the thermal plume, causing an increase in the concentration of contaminants in front of the target person. The results are significantly dependent on the distance and position between the two manikins in all three cases. PRACTICAL IMPLICATIONS: Indoor environments are susceptible to contaminant exposure, as contaminants can easily spread in the air. Human breathing is one of the most important biological contaminant sources, as the exhaled air can contain different pathogens such as viruses and bacteria. This paper addresses the human exhalation flow and its behavior in connection with different ventilation strategies, as well as the interaction between two people in a room. This is a key factor for studying the airborne infection risk when the room is occupied by several persons. The paper only takes into account the airborne part of the infection risk.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Year:  2011        PMID: 21815935     DOI: 10.1111/j.1600-0668.2011.00736.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  21 in total

1.  Speech can produce jet-like transport relevant to asymptomatic spreading of virus.

Authors:  Manouk Abkarian; Simon Mendez; Nan Xue; Fan Yang; Howard A Stone
Journal:  Proc Natl Acad Sci U S A       Date:  2020-09-25       Impact factor: 11.205

2.  Droplet aerosols transportation and deposition for three respiratory behaviors in a typical negative pressure isolation ward.

Authors:  Yongxin Wang; Zhijian Liu; Haiyang Liu; Minnan Wu; Junzhou He; Guoqing Cao
Journal:  Build Environ       Date:  2022-05-30       Impact factor: 7.093

3.  Dispersion and exposure to a cough-generated aerosol in a simulated medical examination room.

Authors:  William G Lindsley; William P King; Robert E Thewlis; Jeffrey S Reynolds; Kedar Panday; Gang Cao; Jonathan V Szalajda
Journal:  J Occup Environ Hyg       Date:  2012       Impact factor: 2.155

4.  Large Eddy Simulation of Air Escape through a Hospital Isolation Room Single Hinged Doorway--Validation by Using Tracer Gases and Simulated Smoke Videos.

Authors:  Pekka E Saarinen; Petri Kalliomäki; Julian W Tang; Hannu Koskela
Journal:  PLoS One       Date:  2015-07-07       Impact factor: 3.240

5.  Assessment of displacement ventilation systems in airborne infection risk in hospital rooms.

Authors:  José Manuel Villafruela; Inés Olmedo; Félix A Berlanga; Manuel Ruiz de Adana
Journal:  PLoS One       Date:  2019-01-30       Impact factor: 3.240

6.  Experimental study on the control effect of different ventilation systems on fine particles in a simulated hospital ward.

Authors:  Xiangfei Kong; Chenli Guo; Zhang Lin; Shasha Duan; Junjie He; Yue Ren; Jianlin Ren
Journal:  Sustain Cities Soc       Date:  2021-06-17       Impact factor: 7.587

7.  TR-PIV measurement of exhaled flow using a breathing thermal manikin.

Authors:  Lianyuan Feng; Shiyong Yao; Hejiang Sun; Nan Jiang; Junjie Liu
Journal:  Build Environ       Date:  2015-11-10       Impact factor: 6.456

8.  An innovative personalized displacement ventilation system for airliner cabins.

Authors:  Ruoyu You; Yongzhi Zhang; Xingwang Zhao; Chao-Hsin Lin; Daniel Wei; Junjie Liu; Qingyan Chen
Journal:  Build Environ       Date:  2018-03-30       Impact factor: 6.456

9.  Human exhalation characterization with the aid of schlieren imaging technique.

Authors:  Chunwen Xu; Peter V Nielsen; Li Liu; Rasmus L Jensen; Guangcai Gong
Journal:  Build Environ       Date:  2016-11-19       Impact factor: 6.456

10.  Role of air changes per hour (ACH) in possible transmission of airborne infections.

Authors:  Farhad Memarzadeh; Weiran Xu
Journal:  Build Simul       Date:  2011-12-22       Impact factor: 3.751

View more