Literature DB >> 21815396

Validation of CT brain perfusion methods using a realistic dynamic head phantom.

Alan J Riordan1, Mathias Prokop, Max A Viergever, Jan Willem Dankbaar, Ewoud J Smit, Hugo W A M de Jong.   

Abstract

PURPOSE: Development and evaluation of a realistic hybrid head phantom for the validation of quantitative CT brain perfusion methods.
METHODS: A combination, or hybrid, of CT images of an anthropomorphic head phantom together with clinically acquired MRI brain images was used to construct a dynamic hybrid head phantom. Essential CT imaging parameters such as spatially dependent noise, effects of resolution, tube settings, and reconstruction parameters were intrinsically included by scanning a skull phantom using CT perfusion (CTP) protocols with varying mAs. These data were combined with processed high resolution 7T clinical MRI images to include healthy and diseased brain parenchyma, as well as the cerebral vascular system. Time attenuation curves emulating contrast bolus passage based on perfusion as observed in clinical studies were added. Using the phantom, CTP images were generated using three brain perfusion calculation methods: bcSVD, sSVD, and fit-based deconvolution, and the linearity and accuracy of the three calculation methods was assessed. Dependency of perfusion outcome on calculation method was compared to clinical data. Furthermore, the potential of the phantom to optimize brain perfusion packages was investigated.
RESULTS: All perfusion calculation methods showed overestimation of low perfusion values and underestimation of high perfusion values. Good correlation in behavior between phantom and clinical data was found (R2 = 0.84).
CONCLUSIONS: A dynamic hybrid head phantom constructed from CT and MRI data was demonstrated to realistically represent clinical CTP studies, which is useful for assessing CT brain perfusion acquisition, reconstruction, and analysis.

Entities:  

Mesh:

Year:  2011        PMID: 21815396     DOI: 10.1118/1.3592639

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Standardization of Stroke Perfusion CT for Reperfusion Therapy.

Authors:  Guangming Zhu; Patrik Michel; Weiwei Zhang; Max Wintermark
Journal:  Transl Stroke Res       Date:  2012-03-28       Impact factor: 6.829

2.  The effect of head movement on CT perfusion summary maps: simulations with CT hybrid phantom data.

Authors:  F Fahmi; A Riordan; L F M Beenen; G J Streekstra; N Y Janssen; H W de Jong; C B L Majoie; E van Bavel; H A Marquering
Journal:  Med Biol Eng Comput       Date:  2013-10-30       Impact factor: 2.602

3.  CT brain perfusion protocol to eliminate the need for selecting a venous output function.

Authors:  A J Riordan; E Bennink; M A Viergever; B K Velthuis; J W Dankbaar; H W A M de Jong
Journal:  AJNR Am J Neuroradiol       Date:  2013-01-31       Impact factor: 3.825

4.  Iterative reconstruction for CT perfusion with a prior-image induced hybrid nonlocal means regularization: Phantom studies.

Authors:  Bin Li; Qingwen Lyu; Jianhua Ma; Jing Wang
Journal:  Med Phys       Date:  2016-04       Impact factor: 4.071

5.  Inferring CT perfusion parameters and uncertainties using a Bayesian approach.

Authors:  Tao Sun; Roger Fulton; Zhanli Hu; Christina Sutiono; Dong Liang; Hairong Zheng
Journal:  Quant Imaging Med Surg       Date:  2022-01

6.  Effect of extended CT perfusion acquisition time on ischemic core and penumbra volume estimation in patients with acute ischemic stroke due to a large vessel occlusion.

Authors:  Jordi Borst; Henk A Marquering; Ludo F M Beenen; Olvert A Berkhemer; Jan Willem Dankbaar; Alan J Riordan; Charles B L M Majoie
Journal:  PLoS One       Date:  2015-03-19       Impact factor: 3.240

7.  A 4D CT digital phantom of an individual human brain for perfusion analysis.

Authors:  Rashindra Manniesing; Christoph Brune; Bram van Ginneken; Mathias Prokop
Journal:  PeerJ       Date:  2016-11-30       Impact factor: 2.984

8.  Patient-based 4D digital breast phantom for perfusion contrast-enhanced breast CT imaging.

Authors:  Marco Caballo; Ritse Mann; Ioannis Sechopoulos
Journal:  Med Phys       Date:  2018-09-19       Impact factor: 4.071

9.  Effect of prolonged acquisition intervals for CT-perfusion analysis methods in patients with ischemic stroke.

Authors:  Fasco van Ommen; Frans Kauw; Edwin Bennink; Jan Willem Dankbaar; Max A Viergever; Hugo W A M de Jong
Journal:  Med Phys       Date:  2019-05-27       Impact factor: 4.071

10.  Variation in arterial input function in a large multicenter computed tomography perfusion study.

Authors:  Daan Peerlings; Edwin Bennink; Jan W Dankbaar; Birgitta K Velthuis; Hugo W A M de Jong
Journal:  Eur Radiol       Date:  2021-05-28       Impact factor: 5.315

  10 in total