Exact Efficient Handling of Interrupted Illumination in Helical Cone-Beam Computed Tomography with Arbitrary Pitch.

Harald Schöndube1, Karl Stierstorfer, Frédéric Noo.   

Abstract

We present a theoretically-exact and stable computed tomography (CT) reconstruction algorithm that is capable of handling interrupted illumination and therefore of using all measured data at arbitrary pitch. This algorithm is based on a differentiated backprojection (DBP) on M-lines. First, we discuss the problem of interrupted illumination and how it affects the DBP. Then we show that it is possible to take advantage of some properties of the DBP to compensate for the effects of interrupted illumination in a mathematically exact way. From there, we have developed an efficient algorithm which we have successfully implemented. We show encouraging preliminary results using both computer-simulated data and real data. Our results show that our method is capable of achieving a substantial reduction of image noise when decreasing the helix pitch compared with the maximum pitch case. We conclude that the proposed algorithm defines for the first time a theoretically-exact and stable reconstruction method that is capable of beneficially using all measured data at arbitrary pitch.

Entities:  

Year:  2010        PMID: 21814455      PMCID: PMC3148095          DOI: 10.1016/S1007-0214(10)70006-7

Source DB:  PubMed          Journal:  Tsinghua Sci Technol        ISSN: 1007-0214            Impact factor:   2.016


  10 in total

1.  The n-PI-method for helical cone-beam CT.

Authors:  R Proksa; T Köhler; M Grass; J Timmer
Journal:  IEEE Trans Med Imaging       Date:  2000-09       Impact factor: 10.048

2.  A quasiexact reconstruction algorithm for helical CT using a 3-Pi acquisition.

Authors:  Claas Bontus; Thomas Köhler; Roland Proksa
Journal:  Med Phys       Date:  2003-09       Impact factor: 4.071

3.  Analysis of an exact inversion algorithm for spiral cone-beam CT.

Authors:  Alexander Katsevich
Journal:  Phys Med Biol       Date:  2002-08-07       Impact factor: 3.609

4.  On two versions of a 3-pi algorithm for spiral CT.

Authors:  Alexander Katsevich
Journal:  Phys Med Biol       Date:  2004-06-07       Impact factor: 3.609

5.  Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT.

Authors:  Yu Zou; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2004-03-21       Impact factor: 3.609

6.  Cone-beam reconstruction using the backprojection of locally filtered projections.

Authors:  Jed D Pack; Frédéric Noo; Rolf Clackdoyle
Journal:  IEEE Trans Med Imaging       Date:  2005-01       Impact factor: 10.048

7.  A general exact reconstruction for cone-beam CT via backprojection-filtration.

Authors:  Yangbo Ye; Shiying Zhao; Hengyong Yu; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2005-09       Impact factor: 10.048

8.  EnPiT: filtered back-projection algorithm for helical CT using an n-Pi acquisition.

Authors:  Claas Bontus; Thomas Köhler; Roland Proksa
Journal:  IEEE Trans Med Imaging       Date:  2005-08       Impact factor: 10.048

9.  Exact cone beam CT with a spiral scan.

Authors:  K C Tam; S Samarasekera; F Sauer
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

10.  Accurate helical cone-beam CT reconstruction with redundant data.

Authors:  Harald Schöndube; Karl Stierstorfer; Frédéric Noo
Journal:  Phys Med Biol       Date:  2009-07-10       Impact factor: 3.609

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.