OBJECTIVE: Currently, pediatric emergency medicine (PEM) physicians have limited data on point-of-care echocardiography (POCE). Our goals were to (1) determine the overall accuracy of POCE by PEMs in assessing left ventricular (LV) systolic function visually, presence or absence of pericardial effusion, and cardiac preload by estimating inferior vena cava (IVC) collapsibility, in acutely ill children in the pediatric emergency department; and (2) assess interobserver agreement between the PEM physician and pediatric cardiologist.
METHODS: This is a prospective, observational study conducted in an urban, tertiary pediatric facility with an annual census of 67,000 emergency department visits. Patients between the ages of 0 and 18 years meeting 1 or more of the following inclusion criteria were recruited: (1) cardiopulmonary arrest, (2) fluid refractory shock requiring vasoactive infusions, (3) undifferentiated cardiomegaly on chest radiography, and (4) receiving emergent formal echocardiography. All eligible patients underwent POCE by 1 of 2 trained PEM physicians. Dynamic video clips were recorded and reviewed by a pediatric cardiologist who was unaware of the clinical condition of the study patients.
RESULTS: For a period of 18 months, we recruited 70 patients. Diminished LV function was noted in 17, pericardial effusion in 16, and abnormal IVC collapsibility in 35 patients. The κ statistics of agreement between the PEM and the cardiologist for detection of LV function, IVC collapsibility, and effusion were 0.87 (95% confidence interval [CI], 0.73-1.00), 0.73 (95% CI, 0.59-0.88), and 0.77 (95% CI, 0.58-0.95), respectively. The overall sensitivity and specificity of POCE compared with a formal echocardiogram was 95% (95% CI, 82%-99%) and 83% (95% CI, 64%-93%), respectively.
CONCLUSIONS: With goal-directed training, PEM physicians may be able to perform POCE and accurately assess for significant LV systolic dysfunction, vascular filling, and the presence of pericardial effusion. The model may be expanded to train physicians to use POCE.

Entities:  

Mesh:

Year:  2011        PMID: 21811201     DOI: 10.1097/PEC.0b013e318226c7c7

Source DB:  PubMed          Journal:  Pediatr Emerg Care        ISSN: 0749-5161            Impact factor:   1.454


  25 in total

1.  Applications of minimally invasive cardiac output monitors.

Authors:  Jahan Porhomayon; Gino Zadeii; Samuel Congello; Nader D Nader
Journal:  Int J Emerg Med       Date:  2012-04-24

Review 2.  Pediatric emergency medicine point-of-care ultrasound: summary of the evidence.

Authors:  Jennifer R Marin; Alyssa M Abo; Alexander C Arroyo; Stephanie J Doniger; Jason W Fischer; Rachel Rempell; Brandi Gary; James F Holmes; David O Kessler; Samuel H F Lam; Marla C Levine; Jason A Levy; Alice Murray; Lorraine Ng; Vicki E Noble; Daniela Ramirez-Schrempp; David C Riley; Turandot Saul; Vaishali Shah; Adam B Sivitz; Ee Tein Tay; David Teng; Lindsey Chaudoin; James W Tsung; Rebecca L Vieira; Yaffa M Vitberg; Resa E Lewiss
Journal:  Crit Ultrasound J       Date:  2016-11-03

3.  Diagnosis of intussusception by physician novice sonographers in the emergency department.

Authors:  Antonio Riera; Allen L Hsiao; Melissa L Langhan; T Rob Goodman; Lei Chen
Journal:  Ann Emerg Med       Date:  2012-03-15       Impact factor: 5.721

4.  Heart failure in dilated cardiomyopathy mimicking asthma triggered by pneumonia.

Authors:  Kenichi Tetsuhara; Satoshi Tsuji; Katsutoshi Nakano; Mitsuru Kubota
Journal:  BMJ Case Rep       Date:  2017-11-09

5.  The authors reply.

Authors:  Thomas W Conlon; David B Kantor; Erik R Su; Akira Nishisaki
Journal:  Pediatr Crit Care Med       Date:  2019-06       Impact factor: 3.624

Review 6.  Fulminant myocarditis associated with the H1N1 influenza virus: case report and literature review.

Authors:  Maria Lúcia Saraiva Lobo; Ângela Taguchi; Heloísa Amaral Gaspar; Juliana Ferreira Ferranti; Werther Brunow de Carvalho; Artur Figueiredo Delgado
Journal:  Rev Bras Ter Intensiva       Date:  2014 Jul-Sep

7.  Expert consensus statement 'Neonatologist-performed Echocardiography (NoPE)'-training and accreditation in UK.

Authors:  Yogen Singh; Samir Gupta; Alan M Groves; Anjum Gandhi; John Thomson; Shakeel Qureshi; John M Simpson
Journal:  Eur J Pediatr       Date:  2015-09-12       Impact factor: 3.183

8.  The evolution of cardiac point of care ultrasound for the neonatologist.

Authors:  Yogen Singh; Shazia Bhombal; Anup Katheria; Cecile Tissot; María V Fraga
Journal:  Eur J Pediatr       Date:  2021-06-14       Impact factor: 3.183

Review 9.  Is Ocular Sonography a Reliable Method for the Assessment of Elevated Intracranial Pressure in Children?

Authors:  Dincer Yildizdas; Nagehan Aslan
Journal:  J Pediatr Intensive Care       Date:  2020-09-07

10.  Point-of-Care Ultrasound Assists in Rapid Diagnosis of T-cell Lymphoblastic Lymphoma in a Young Boy.

Authors:  Ceyda H Sablak; Rebecca M Dudley; Alexander Youngdahl; Kevin R Roth
Journal:  Cureus       Date:  2021-05-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.