Prematurely condensed chromosome rings after neutron irradiation of human lymphocytes.

Ana I Lamadrid1, Jorge E González, Omar García, Philippe Voisin, Laurence Roy.   

Abstract

Calibration curves for fission spectrum neutrons and other high LET radiations are scarce in cytogenetic dosimetry and particularly for Prematurely Condensed Chromosome Rings (PCC-ring). Here we analyzed the behavior of the PCC-ring frequency and PCC index after neutron irradiation in a broad dose interval from 1 to 26 Gy. PCC-rings were induced in lymphocytes with Calyculin A. 6455 PCC cells in G1, G2/M and M/A stages were analyzed. The best fitting between the frequency of PCC ring (Y) and the Dose (D) was obtained with the equation Y = (0.059 ± 0.003) D. The saturation of the PCC-ring was observed after around 4 Gy, but it was still possible to analyze cells exposed up to 26 Gy. The distribution of rings by cell follows Poisson or Neyman type distribution for all doses. This PCC-ring dose effect curve can be used in case of accidental overexposure to neutron radiation, allowing a dose assessment in a reliable way. Additionally, the PCC index seems to be well correlated with radiation dose and decrease in a dose dependent manner from 13% in non exposed sample down to 0.2%. This observation allows the possibility to perform a quick classification of victims exposed to high doses of both gamma and neutron radiations. The PCC assay can then be used for both neutron dose estimation up to 4 Gy and for the rapid classification of victims exposed to higher doses. This assay could be included in the multiparametric approach developed to optimize the medical treatment of radiation victims.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21811043     DOI: 10.1269/jrr.10096

Source DB:  PubMed          Journal:  J Radiat Res        ISSN: 0449-3060            Impact factor:   2.724


  3 in total

1.  Visualizing Active Replication Regions in S-Phase Chromosomes.

Authors:  Eisuke Gotoh
Journal:  Methods Mol Biol       Date:  2023

2.  A new model of biodosimetry to integrate low and high doses.

Authors:  Mònica Pujol; Joan-Francesc Barquinero; Pedro Puig; Roser Puig; María Rosa Caballín; Leonardo Barrios
Journal:  PLoS One       Date:  2014-12-02       Impact factor: 3.240

3.  Assessment of simulated high-dose partial-body irradiation by PCC-R assay.

Authors:  Ivonne Romero; Omar García; Ana I Lamadrid; Eric Gregoire; Jorge E González; Wilfredo Morales; Cécile Martin; Joan-Francesc Barquinero; Philippe Voisin
Journal:  J Radiat Res       Date:  2013-04-17       Impact factor: 2.724

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.