Study of flow-induced hemolysis using novel Couette-type blood-shearing devices.

Tao Zhang1, M Ertan Taskin, Hong-Bin Fang, Adam Pampori, Robert Jarvik, Bartley P Griffith, Zhongjun J Wu.   

Abstract

To assist the development and application of blood-contacting medical devices, two novel flow-through Couette-type blood-shearing devices have been developed to study the quantitative relationship between blood damage indexes and flow-dependent parameters. One device is an axial flow-through Couette-type device supported by a pair of pin bearings adapted from the adult Jarvik 2000 blood pump. The other is a centrifugal flow-through Couette-type device supported with magnetic bearings adapted from the CentriMag blood pump. In both devices, a rotor spindle was used to replace the original impeller blades so that a small gap was created between the housing and the rotating spindle surface. Computational fluid dynamics simulations have shown that a uniform, high shear stress region can be generated inside the small gap while the shear stresses elsewhere are relatively low. The possibility of secondary blood damage caused by mechanical seals was eliminated due to the use of a magnetic rotor system. Blood flow through the gap was driven by an externally pressurized reservoir. By adjusting the rotational speed and blood flow rate, shear-induced hemolysis was quantified at a matrix of exposure time (0.039 to 1.48 s) and shear stress (50 to 320 Pa). All of the experiments were conducted at room temperature using heparinized ovine blood with a hematocrit value of 30%. The measured hemolysis levels were much lower than those published in the literature, and the overestimation of those earlier studies may be attributable to device-related secondary blood-damaging effects. A new set of coefficients for the power law model was derived from the regression of the experimental data.
© 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21810113     DOI: 10.1111/j.1525-1594.2011.01243.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  20 in total

1.  Shear stress and blood trauma under constant and pulse-modulated speed CF-VAD operations: CFD analysis of the HVAD.

Authors:  Zengsheng Chen; Sofen K Jena; Guruprasad A Giridharan; Michael A Sobieski; Steven C Koenig; Mark S Slaughter; Bartley P Griffith; Zhongjun J Wu
Journal:  Med Biol Eng Comput       Date:  2018-11-08       Impact factor: 2.602

2.  A Cellular Model of Shear-Induced Hemolysis.

Authors:  Salman Sohrabi; Yaling Liu
Journal:  Artif Organs       Date:  2017-01-03       Impact factor: 3.094

3.  High shear induces platelet dysfunction leading to enhanced thrombotic propensity and diminished hemostatic capacity.

Authors:  Zengsheng Chen; Nandan K Mondal; Shirong Zheng; Steven C Koenig; Mark S Slaughter; Bartley P Griffith; Zhongjun J Wu
Journal:  Platelets       Date:  2017-11-28       Impact factor: 3.862

4.  Assessing Computational Model Credibility Using a Risk-Based Framework: Application to Hemolysis in Centrifugal Blood Pumps.

Authors:  Tina M Morrison; Prasanna Hariharan; Chloe M Funkhouser; Payman Afshari; Mark Goodin; Marc Horner
Journal:  ASAIO J       Date:  2019 May/Jun       Impact factor: 2.872

5.  Production of erythrocyte microparticles in a sub-hemolytic environment.

Authors:  James P Buerck; Dustin K Burke; David W Schmidtke; Trevor A Snyder; Dimitrios V Papavassiliou; Edgar A O'Rear
Journal:  J Artif Organs       Date:  2021-01-09       Impact factor: 1.731

6.  Prediction of mechanical hemolysis in medical devices via a Lagrangian strain-based multiscale model.

Authors:  Mehdi Nikfar; Meghdad Razizadeh; Jiafeng Zhang; Ratul Paul; Zhongjun J Wu; Yaling Liu
Journal:  Artif Organs       Date:  2020-03-05       Impact factor: 3.094

Review 7.  Recent advances in computational methodology for simulation of mechanical circulatory assist devices.

Authors:  Alison L Marsden; Yuri Bazilevs; Christopher C Long; Marek Behr
Journal:  Wiley Interdiscip Rev Syst Biol Med       Date:  2014-01-21

8.  Multilaboratory study of flow-induced hemolysis using the FDA benchmark nozzle model.

Authors:  Luke H Herbertson; Salim E Olia; Amanda Daly; Christopher P Noatch; William A Smith; Marina V Kameneva; Richard A Malinauskas
Journal:  Artif Organs       Date:  2014-09-02       Impact factor: 3.094

9.  Percutaneous Double Lumen Cannula for Right Ventricle Assist Device System: A Computational Fluid Dynamics Study.

Authors:  Francesca Condemi; Dongfang Wang; Gionata Fragomeni; Fuqian Yang; Guangfeng Zhao; Cameron Jones; Cherry Ballard-Croft; Joseph B Zwischenberger
Journal:  Biocybern Biomed Eng       Date:  2016-04-18       Impact factor: 4.314

10.  Quantitative Characterization of Shear-Induced Platelet Receptor Shedding: Glycoprotein Ibα, Glycoprotein VI, and Glycoprotein IIb/IIIa.

Authors:  Zengsheng Chen; Steven C Koenig; Mark S Slaughter; Bartley P Griffith; Zhongjun J Wu
Journal:  ASAIO J       Date:  2018 Nov/Dec       Impact factor: 2.872

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.