Literature DB >> 21809087

Specific magnetic isolation for direct detection of HPV16.

S Peeters1, T Stakenborg, F Colle, C X Liu, L Lagae, M Van Ranst.   

Abstract

Finding a suitable DNA purification system is vital for the success of many PCR based diagnostic tests. This report demonstrates the value of magnetic beads in combination with real-time PCR for the sequence-specific isolation and detection of episomal HPV16 DNA. In order to maximize the isolation, two purification procedures were evaluated. Compared to the indirect method, in which the target was magnetically labeled after being hybridized to the capture probes, much higher efficiencies were obtained by directly capturing the target using DNA functionalized beads. These higher efficiencies were obtained by carefully tuning the capture probe density on the beads. When modifying the beads with dual-biotinylated capture probes or introducing beads modified with different capture probes, the amount of HPV16 isolated from spiked clinical swab samples even increased further. This not only resulted in the use of dual-biotinylated capture probes in higher purification efficiencies, but also the thermostability of the DNA-bead linkage was found to improve. In summary, this study shows that DNA functionalized magnetic beads are very promising diagnostic tools as they allow for a specific, simple, and fast isolation and concentration of minute quantities of DNA from complex clinical samples.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21809087     DOI: 10.1007/s10096-011-1345-4

Source DB:  PubMed          Journal:  Eur J Clin Microbiol Infect Dis        ISSN: 0934-9723            Impact factor:   3.267


  28 in total

1.  Collection of trace amounts of DNA/mRNA molecules using genomagnetic nanocapturers.

Authors:  Xiaojun Zhao; Rovelyn Tapec-Dytioco; Kemin Wang; Weihong Tan
Journal:  Anal Chem       Date:  2003-07-15       Impact factor: 6.986

2.  An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities.

Authors:  Jin-Woo Choi; Kwang W Oh; Jennifer H Thomas; William R Heineman; H Brian Halsall; Joseph H Nevin; Arthur J Helmicki; H Thurman Henderson; Chong H Ahn
Journal:  Lab Chip       Date:  2001-12-06       Impact factor: 6.799

3.  Comparison of the Digene HC2 assay and the Roche AMPLICOR human papillomavirus (HPV) test for detection of high-risk HPV genotypes in cervical samples.

Authors:  Maria T Sandri; Paola Lentati; Elvira Benini; Patrizia Dell'Orto; Laura Zorzino; Francesca M Carozzi; Patrick Maisonneuve; Rita Passerini; Michela Salvatici; Chiara Casadio; Sara Boveri; Mario Sideri
Journal:  J Clin Microbiol       Date:  2006-06       Impact factor: 5.948

4.  Magnetic bead-based solid phase for selective extraction of genomic DNA.

Authors:  Marie J Archer; Baochuan Lin; Zheng Wang; David A Stenger
Journal:  Anal Biochem       Date:  2006-05-24       Impact factor: 3.365

5.  Use of PGMY primers in L1 consensus PCR improves detection of human papillomavirus DNA in genital samples.

Authors:  François Coutlée; Patti Gravitt; Janet Kornegay; Catherine Hankins; Harriet Richardson; Normand Lapointe; Hélène Voyer; Eduardo Franco
Journal:  J Clin Microbiol       Date:  2002-03       Impact factor: 5.948

6.  Use of multiple PCR primer sets for optimal detection of human papillomavirus.

Authors:  F Karlsen; M Kalantari; A Jenkins; E Pettersen; G Kristensen; R Holm; B Johansson; B Hagmar
Journal:  J Clin Microbiol       Date:  1996-09       Impact factor: 5.948

7.  Viral load of human papilloma virus 16 as a determinant for development of cervical carcinoma in situ: a nested case-control study.

Authors:  A M Josefsson; P K Magnusson; N Ylitalo; P Sørensen; P Qwarforth-Tubbin; P K Andersen; M Melbye; H O Adami; U B Gyllensten
Journal:  Lancet       Date:  2000-06-24       Impact factor: 79.321

8.  Human papillomavirus 16 load in normal and abnormal cervical scrapes: an indicator of CIN II/III and viral clearance.

Authors:  Mark van Duin; Peter J F Snijders; Henri F J Schrijnemakers; Feja J Voorhorst; Lawrence Rozendaal; Marielle A E Nobbenhuis; Adriaan J C van den Brule; René H M Verheijen; Theo J Helmerhorst; Chris J L M Meijer
Journal:  Int J Cancer       Date:  2002-04-01       Impact factor: 7.396

9.  Specific magnetic bead based capture of genomic DNA from clinical samples: application to the detection of group B streptococci in vaginal/anal swabs.

Authors:  Nicholas J Parham; François J Picard; Régis Peytavi; Martin Gagnon; Grégoire Seyrig; Pier-Ann Gagné; Maurice Boissinot; Michel G Bergeron
Journal:  Clin Chem       Date:  2007-07-27       Impact factor: 8.327

Review 10.  Magnetic particles for the separation and purification of nucleic acids.

Authors:  Sonja Berensmeier
Journal:  Appl Microbiol Biotechnol       Date:  2006-10-25       Impact factor: 4.813

View more
  1 in total

1.  Ultrasensitive hybridization capture: Reliable detection of <1 copy/mL short cell-free DNA from large-volume urine samples.

Authors:  Amy Oreskovic; Barry R Lutz
Journal:  PLoS One       Date:  2021-02-26       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.