Literature DB >> 21807497

An integrated chip for rapid, sensitive, and multiplexed detection of cardiac biomarkers from fingerprick blood.

Guo-Jun Zhang1, Zhan Hong Henry Luo, Min Joon Huang, Jun'an Jason Ang, Tae Goo Kang, Hongmiao Ji.   

Abstract

Cardiovascular diseases are the major cause of death among adults worldwide. Electrocardiogram (ECG) is a first test when a patient suffering from chest pain sees a doctor, however, it is lack of the required sensitivity. Standard assays to detect cardiac biomarkers, like enzyme-linked immunosorbent assay (ELISA) are sensitive, but suffer from important sample and reagent consumption in large-scale studies. Moreover they are performed in central laboratories of clinics and hospitals and take a long time, which is highly incompatible with the quick decisions needed to save a heart attack patient. Herein, we describe an integrated chip allowing rapid, sensitive, and simultaneous analysis of three cardiac biomarkers in fingerprick blood. The integrated chip is composed of a filtration chip for plasma separation from blood and a silicon nanowire (SiNW) array sensor chip for protein detection. These two chips are fabricated separately and bonded to form a single unit after alignment. The integrated chip is capable of reducing the dead volume of the sample by eliminating the tubing between the two chips. After the plasma is filtrated by the filtration chip, the SiNW sensor, spotted with three different antibodies, enabled us to detect three cardiac biomarkers, troponin T (cTnT), creatine kinase MM (CK-MM) and creatine kinase MB (CK-MB), simultaneously. The integrated chip is able to attain a low detection limit of 1 pg/ml for the three cardiac biomarkers from 2 μl blood in 45 min.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21807497     DOI: 10.1016/j.bios.2011.07.007

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  An electrochemical troponin T aptasensor based on the use of a macroporous gold nanostructure.

Authors:  Masoud Negahdary; Mostafa Behjati-Ardakani; Hossein Heli
Journal:  Mikrochim Acta       Date:  2019-05-27       Impact factor: 5.833

Review 2.  Nanomaterial-assisted microfluidics for multiplex assays.

Authors:  Yanping Wang; Yanfeng Gao; Yi Yin; Yongchun Pan; Yuzhen Wang; Yujun Song
Journal:  Mikrochim Acta       Date:  2022-03-11       Impact factor: 5.833

Review 3.  Multiplexed Electrochemical Immunosensors for Clinical Biomarkers.

Authors:  Paloma Yáñez-Sedeño; Susana Campuzano; José M Pingarrón
Journal:  Sensors (Basel)       Date:  2017-04-27       Impact factor: 3.576

Review 4.  Recent advances in nanowires-based field-effect transistors for biological sensor applications.

Authors:  Rafiq Ahmad; Tahmineh Mahmoudi; Min-Sang Ahn; Yoon-Bong Hahn
Journal:  Biosens Bioelectron       Date:  2017-09-18       Impact factor: 10.618

5.  Sensitive impedimetric detection of troponin I with metal-organic framework composite electrode.

Authors:  Arushi Gupta; Sandeep Kumar Sharma; Vivek Pachauri; Sven Ingebrandt; Suman Singh; Amit L Sharma; Akash Deep
Journal:  RSC Adv       Date:  2021-01-08       Impact factor: 3.361

Review 6.  The Role of Flavonoids as a Cardioprotective Strategy against Doxorubicin-Induced Cardiotoxicity: A Review.

Authors:  Rony Abdi Syahputra; Urip Harahap; Aminah Dalimunthe; M Pandapotan Nasution; Denny Satria
Journal:  Molecules       Date:  2022-02-15       Impact factor: 4.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.