Literature DB >> 21806755

A new approach to compare the esthetic properties of different composite materials.

Niels Østervemb1, Jette Nedergaard Jørgensen, Preben Hørsted-Bindslev.   

Abstract

STATEMENT OF THE PROBLEM: Modern composite systems are either very simple with few shades or very complex with an array of shades. Which approach gives the best esthetic results?
PURPOSE: The study aims to use a new approach to compare the esthetic properties of different composite materials and evaluate the ability of four different composite systems to imitate the natural shade of teeth.
MATERIALS AND METHODS: Seventeen extracted teeth were restored using four different composite materials (Filtek Supreme XT [3M ESPE, Glostrup, Denmark], Ceram-X Duo [Dentsply-Friadent, Roskilde, Denmark], Tetric EvoCeram [Ivoclar Vivadent AB, Solna, Sweden], Enamel Plus HRI [Micerium, Avegno, Italy]). In total, 68 restorations were fabricated using the 17 teeth as their own control. This was made possible utilizing a device designed to remove exactly the same piece of tooth/composite every time. The time for placement and shades used were recorded. Two dentists evaluated the esthetic match of the restorations using slightly modified Extended Visual Rating Scale for Appearance Match criteria.
RESULTS: There was a statistically significant difference (p ≤ 0.05) between Filtek Supreme XT and Tetric EvoCeram and between Enamel Plus HRI and Tetric EvoCeram regarding the esthetic match. However, this was not deemed clinically relevant in most cases. Filtek Supreme XT required the most time, whereas Ceram-X Duo required the least time. There was a high intra- and interobserver agreement regarding ratings.
CONCLUSION: The study concluded that: (1) it was possible with all four composite systems to make restorations that were judged clinically acceptable in 91 to 96% of the cases; (2) more time was needed when using the more "advanced systems"; and (3) the new standardized, simple, and clinically relevant evaluation method was capable of comparing different composite systems' ability to imitate natural teeth.
© 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21806755     DOI: 10.1111/j.1708-8240.2010.00398.x

Source DB:  PubMed          Journal:  J Esthet Restor Dent        ISSN: 1496-4155            Impact factor:   2.843


  1 in total

1.  A 4-year clinical evaluation of direct composite build-ups for space closure after orthodontic treatment.

Authors:  Mustafa Demirci; Safa Tuncer; Evren Öztaş; Neslihan Tekçe; Ömer Uysal
Journal:  Clin Oral Investig       Date:  2015-03-24       Impact factor: 3.573

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.