Literature DB >> 21804521

Electrosurgical smoke: a real concern.

K K Chowdhury1, S M Meftahuzzaman, D Rickta, T K Chowdhury, B B Chowdhury, S T Ireen.   

Abstract

Electrosurgical techniques including laser surgery have expanded greatly in recent years. Pyrolysis of tissue produces smoke. Recently the smoke is being analyzed using Gas Chromatography-Mass Spectrometry. The nature of smoke depends on the rise of temperature of tissue during electro-surgery. The smoke produced at high temperatures contains low concentration of Group-I carcinogens (IARC) such as Benzene, Hydrogen cyanide, Formaldehyde 1,3-Butadiene and Acrylonitrile. Bioaerosol produced at low temperature as in harmonic scissors may contain live multidrug resistant Mycobacterium tuberculosis, viral DNA of HBV, HCV, HIV and HPV. It also contains live malignant cells and dead cellular materials. These produce an unquantified infection risk. The obnoxious smoke causes ocular and upper respiratory tract irritation, creates visual problems for surgeons. Surgical masks are not capable of filtering the produced bioaerosol. Removal of smoke from the site of operation by local exhaust ventilation is not complete. When produced in a closed cavity as in laparoscopic surgery the patient also suffers from carboxyhaemoglobinaemia and methaemoglobinaemia. Methemoglobinaemia is not detected by standard pulse-oximetry. Laser smoke produces congestive interstitial pneumonia, bronchiolitis and emphysema in rats. Chromosomal aberration and sister chromatid exchange have been found in lymphocyte culture of operating room personnel. Occupational safety and health authorities like Occupational Safety and Health Administration (OSHA), National Institute for Occupational safety and Health (NIOSH), American National Standard Institute (ANSI) and Association of Operating room nurses (AORN) are trying to find effective ways for removal of smoke from site of operation and also the real risk to operating room personnel. Answer lies in minimizing the use of electrocautery whenever possible and completes removal of harmful smoke.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21804521

Source DB:  PubMed          Journal:  Mymensingh Med J        ISSN: 1022-4742


  3 in total

1.  Biomedical nanostructured coating for minimally invasive surgery devices applications: characterization, cell cytotoxicity evaluation and an animal study in rat.

Authors:  Keng-Liang Ou; Jan-Show Chu; Hossein Hosseinkhani; Jeng-Fong Chiou; Chih-Hua Yu
Journal:  Surg Endosc       Date:  2014-03-12       Impact factor: 4.584

2.  Laminar air flow reduces particle load in TKA-even outside the LAF panel: a prospective, randomized cohort study.

Authors:  Stephanie Kirschbaum; Hagen Hommel; Peggy Strache; Roland Horn; Roman Falk; Carsten Perka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-11-09       Impact factor: 4.342

3.  Easy-to-use electrocautery smoke evacuation device for open surgery under the risk of the COVID-19 pandemic.

Authors:  Baki Ekci
Journal:  J Int Med Res       Date:  2020-08       Impact factor: 1.671

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.