Literature DB >> 21804435

Quantification of non-polar lipid deposits on senofilcon a contact lenses.

Miriam Heynen1, Holly Lorentz, Sruthi Srinivasan, Lyndon Jones.   

Abstract

PURPOSE: To quantify non-polar lipids deposited on senofilcon A silicone hydrogel contact lenses (J&J Acuvue OASYS) when disinfected with a no-rub one-step hydrogen peroxide system (CIBA Vision ClearCare) and a care system preserved with Polyquad & Aldox (Alcon OPTI-FREE RepleniSH).
METHODS: Thirty existing soft lens wearers symptomatic of dryness were enrolled into a 4-week prospective, randomized, bilateral eye (lens type), cross-over (care regimen), daily wear, double masked study. Subjects were refitted with senofilcon A lenses, which were replaced biweekly. During each period of wear, participants used either the peroxide or preserved system. After each period of wear, lenses were collected and lipid was extracted using 1.5 ml of a 2:1 chloroform:methanol solution for 3 h at 37 °C. Lens extracts were analyzed for non-polar lipids [cholesterol oleate (CO), cholesterol, oleic acid (OA), triolein, and OA methyl ester] using normal phase high-performance liquid chromatography.
RESULTS: The total lipid (sum of CO and cholesterol) detected was 34 ± 28 μg/lens for the peroxide-based system and 22 ± 21 μg/lens for the system preserved with Polyquad and Aldox (p = 0.029). Although there was no difference between products for cholesterol (1.4 vs. 1.3 μg/lens; p = 0.50), use of a system preserved with Polyquad and Aldox resulted in significantly less deposited CO (33 ± 28 vs. 21 ± 20 μg/lens; p = 0.033). Approximately, 95% of the detectable lipid deposited on the material was CO, followed by cholesterol. OA and triolein contributed <1% of the total lipid and no OA methyl ester was found on any of the lenses.
CONCLUSIONS: A care system preserved with Polyquad and Aldox removed higher amounts of CO from senofilcon A contact lenses used for 2 weeks than a peroxide-based system, in soft lens wearers who were symptomatic of dry eye.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21804435     DOI: 10.1097/OPX.0b013e31822a5295

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  5 in total

1.  In vitro Evaluation of the Location of Cholesteryl Ester Deposits on Monthly Replacement Silicone Hydrogel Contact Lens Materials.

Authors:  Han Qiao; Doerte Luensmann; Miriam Heynen; Elizabeth Drolle; Lakshman N Subbaraman; Charles Scales; Donald Riederer; Zohra Fadli; Lyndon Jones
Journal:  Clin Ophthalmol       Date:  2020-09-24

2.  Activity of Deposited Lysozyme on Contemporary Soft Contact Lenses Exposed to Differing Lens Care Systems.

Authors:  Miriam Heynen; Alan Ng; Elizabeth Martell; Lakshman N Subbaraman; Lyndon Jones
Journal:  Clin Ophthalmol       Date:  2021-04-23

3.  Quantification of individual proteins in silicone hydrogel contact lens deposits.

Authors:  Negar Babaei Omali; Zhenjun Zhao; Hua Zhu; Daniel Tilia; Mark D P Willcox
Journal:  Mol Vis       Date:  2013-02-18       Impact factor: 2.367

4.  A Rapid Extraction Method to Quantify Drug Uptake in Contact Lenses.

Authors:  Chau-Minh Phan; Sarah Weber; Jennifer Mueller; Alan Yee; Lyndon Jones
Journal:  Transl Vis Sci Technol       Date:  2018-03-23       Impact factor: 3.283

5.  Differential Deposition of Fluorescently Tagged Cholesterol on Commercial Contact Lenses Using a Novel In Vitro Eye Model.

Authors:  Hendrik Walther; Chau-Minh Phan; Lakshman N Subbaraman; Lyndon Jones
Journal:  Transl Vis Sci Technol       Date:  2018-04-05       Impact factor: 3.283

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.