Literature DB >> 21803594

Effect on false-lumen status of a combined vascular and endovascular approach for the treatment of acute type A aortic dissection.

Martin Czerny1, Sybilla Stöhr, Thierry Aymard, Gottfried H Sodeck, Marek Ehrlich, Tomasz Dziodzio, Andrzej Juraszek, Thierry Carrel.   

Abstract

OBJECTIVE: The aim of the study is to evaluate midterm results with regard to false-lumen status of a combined vascular and endovascular approach for the treatment of acute type A aortic dissection.
METHODS: We performed ascending/hemiarch replacement during hypothermic circulatory arrest with additional open implantation of the Djumbodis Dissection System (non-self-expanding bare metal stent) to readapt the dissected layers in the arch and the proximal descending aorta in a consecutive series of 15 patients (mean age 61 years, 20% female) suffering from acute type A aortic dissections. The primary end point was the status of the false lumen at the level of the stent.
RESULTS: We observed three in-hospital deaths (20%). Complete thrombosis of the false lumen was observed in one patient (8%). In 25% of patients, partial thrombosis of the false lumen was observed. The remaining patients had continuing antegrade perfusion. Surgical conversion during a mean follow-up of 37 months was required in two patients (16%) due to continuing enlargement of the distal arch and the proximal descending aorta. No late deaths were observed.
CONCLUSION: Additional implantation of the Djumbodis Dissection System to readapt the dissected layers in the arch and the proximal descending aorta does not seem to have additive value as an adjunct to standard ascending/hemiarch replacement with regard to closure of the false lumen in the arch and the proximal descending aorta. The most limiting factor seems to be the non-self-expanding capability of the device.

Entities:  

Mesh:

Year:  2011        PMID: 21803594     DOI: 10.1016/j.ejcts.2011.05.063

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  1 in total

1.  Associated bare stenting of distal aorta with a Djumbodis(®) system versus conventional surgery in type A aortic dissection.

Authors:  Thierry Caus; Dmitry Sirota; Joseph Nader; Maxim Lyashenko; Alexander Chernyavsky
Journal:  Ann Cardiothorac Surg       Date:  2016-07
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.