Evaluation of hyperspectral technology for assessing the presence and severity of peripheral artery disease.

Jason A Chin1, Edward C Wang, Melina R Kibbe.   

Abstract

BACKGROUND: Hyperspectral imaging is a novel technology that can noninvasively measure oxyhemoglobin and deoxyhemoglobin concentrations to create an anatomic oxygenation map. It has predicted healing of diabetic foot ulcers; however, its ability to assess peripheral arterial disease (PAD) has not been studied. The aims of this study were to determine if hyperspectral imaging could accurately assess the presence or absence of PAD and accurately predict PAD severity.
METHODS: This prospective study included consecutive consenting patients presenting to the vascular laboratory at the Jesse Brown VA Medical Center during a 10-week period for a lower extremity arterial study, including ankle-brachial index (ABI) and Doppler waveforms. Patients with lower extremity edema were excluded. Patients underwent hyperspectral imaging at nine angiosomes on each extremity. Additional sites were imaged when tissue loss was present. Medical records of enrolled patients were reviewed for demographic data, active medications, surgical history, and other information pertinent to PAD. Patients were separated into no-PAD and PAD groups. Differences in hyperspectral values between the groups were evaluated using the two-tailed t test. Analysis for differences in values over varying severities of PAD, as defined by triphasic, biphasic, or monophasic Doppler waveforms, was conducted using one-way analysis of variance. Hyperspectral values were correlated with the ABI using a Pearson bivariate linear correlation test.
RESULTS: The study enrolled 126 patients (252 limbs). After exclusion of 15 patients, 111 patients were left for analysis, including 46 (92 limbs) no-PAD patients and 65 (130 limbs) PAD patients. Groups differed in age, diabetes, coronary artery disease, congestive heart failure, tobacco use, and insulin use. Deoxyhemoglobin values for the plantar metatarsal, arch, and heel angiosomes were significantly different between patients with and without PAD (P < .005). Mean deoxyhemoglobin values for the same three angiosomes showed significant differences between patients with monophasic, biphasic, and triphasic waveforms (P < .05). In patients with PAD, there was also significant correlation between deoxyhemoglobin values and ABI for the same three angiosomes (P = .001). Oxyhemoglobin values did not predict the presence or absence of PAD, did not correlate with PAD severity, and did not correlate with the ABI.
CONCLUSIONS: These results suggest the ability of hyperspectral imaging to detect the presence of PAD. Hyperspectral measurements can also evaluate different severities of PAD. Published by Mosby, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21803525     DOI: 10.1016/j.jvs.2011.06.022

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  16 in total

1.  Snapshot hyperspectral retinal imaging using compact spectral resolving detector array.

Authors:  Hao Li; Wenzhong Liu; Biqin Dong; Joel V Kaluzny; Amani A Fawzi; Hao F Zhang
Journal:  J Biophotonics       Date:  2016-07-19       Impact factor: 3.207

2.  Continuous monitoring of interstitial tissue oxygen using subcutaneous oxygen microsensors: In vivo characterization in healthy volunteers.

Authors:  Stephen C Kanick; Peter A Schneider; Bruce Klitzman; Natalie A Wisniewski; Kerstin Rebrin
Journal:  Microvasc Res       Date:  2019-02-08       Impact factor: 3.514

Review 3.  Medical hyperspectral imaging: a review.

Authors:  Guolan Lu; Baowei Fei
Journal:  J Biomed Opt       Date:  2014-01       Impact factor: 3.170

4.  Hyperspectral imaging in wound care: A systematic review.

Authors:  Gennadi Saiko; Phoebe Lombardi; Yunghan Au; Douglas Queen; David Armstrong; Keith Harding
Journal:  Int Wound J       Date:  2020-08-23       Impact factor: 3.315

5.  Intraoperative multispectral and hyperspectral label-free imaging: A systematic review of in vivo clinical studies.

Authors:  Jonathan Shapey; Yijing Xie; Eli Nabavi; Robert Bradford; Shakeel R Saeed; Sebastien Ourselin; Tom Vercauteren
Journal:  J Biophotonics       Date:  2019-04-29       Impact factor: 3.207

6.  Effects of Lower Limb Revascularization on the Microcirculation of the Foot: A Retrospective Cohort Study.

Authors:  Gennady Geskin; Michael D Mulock; Nicole L Tomko; Anna Dasta; Sandeep Gopalakrishnan
Journal:  Diagnostics (Basel)       Date:  2022-05-26

7.  Quantitative Results of Perfusion Utilising Hyperspectral Imaging on Non-diabetics and Diabetics: A Pilot Study.

Authors:  Christina J Lee; Elliot Walters; Christopher J Kennedy; Ariya Beitollahi; Karen K Evans; Christopher E Attinger; Paul J Kim
Journal:  Int Wound J       Date:  2020-08-07       Impact factor: 3.315

8.  Perfusion Assessment in Critical Limb Ischemia: Principles for Understanding and the Development of Evidence and Evaluation of Devices: A Scientific Statement From the American Heart Association.

Authors:  Sanjay Misra; Mehdi H Shishehbor; Edwin A Takahashi; Herbert D Aronow; Luke P Brewster; Matthew C Bunte; Esther S H Kim; Jonathan R Lindner; Kathleen Rich
Journal:  Circulation       Date:  2019-08-12       Impact factor: 29.690

9.  A pilot study on effects of acupuncture and moxibustion by hyperspectral imaging technique.

Authors:  Dong Zhang; Yin-Long Li; Shu-You Wang; Xiao-Dong Bai; Xiao-Jing Song; Shun-Yue Li
Journal:  Evid Based Complement Alternat Med       Date:  2014-12-03       Impact factor: 2.629

10.  Rice Seed Purity Identification Technology Using Hyperspectral Image with LASSO Logistic Regression Model.

Authors:  Weihua Liu; Shan Zeng; Guiju Wu; Hao Li; Feifei Chen
Journal:  Sensors (Basel)       Date:  2021-06-26       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.