Literature DB >> 21803319

Propensity-matched patient-level comparison of the TAXUS Liberté and TAXUS element (ION) paclitaxel-eluting stents.

Dean J Kereiakes1, Louis A Cannon, John A Ormiston, Mark A Turco, Tift Mann, Gregory J Mishkel, Thomas McGarry, Hong Wang, Paul Underwood, Keith D Dawkins.   

Abstract

Stent design, metal alloy composition, and strut thickness may influence late lumen loss and clinical outcomes after bare metal stent deployment; however, their impact on outcomes after drug-eluting stent deployment is unknown. Although the TAXUS Liberté and ION paclitaxel-eluting stents use similar polymer and drug, the ION stent incorporates a novel thin-strut platinum chromium metal alloy and cell design. We therefore compared patient-level data from 2,298 subjects enrolled into the TAXUS ATLAS (TAXUS Liberté) and PERSEUS (ION) clinical trials. Propensity-score (1:1) matching was performed to adjust for covariate imbalance between stent types. Twelve-month major adverse cardiac events were less frequent after use of the ION compared to the TAXUS Liberté (12.7% vs 8.3%, p <0.001, unadjusted; 12.0% vs 7.5%, p = 0.007, propensity matched) largely because of decreased non-Q-wave myocardial infarction (MI; 2.9% vs 1.4%, p = 0.01, unadjusted; 3.2% vs 0.9%, p = 0.004, propensity matched). The MI difference was predominantly periprocedural and in patients treated with a single stent. In conclusion, this exploratory post hoc analysis demonstrated that the ION was associated with fewer adverse clinical events than the TAXUS Liberté because of decreased non-Q-wave MI. Stent platform-related variables may influence clinical outcomes after drug-eluting stent use despite similar polymer and drug elution. Differences in adjunctive pharmacotherapy and/or stenting technique may also be contributory.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21803319     DOI: 10.1016/j.amjcard.2011.05.011

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  2 in total

Review 1.  The effect of mechanical loads on the degradation of aliphatic biodegradable polyesters.

Authors:  Ying Li; Zhaowei Chu; Xiaoming Li; Xili Ding; Meng Guo; Haoran Zhao; Jie Yao; Lizhen Wang; Qiang Cai; Yubo Fan
Journal:  Regen Biomater       Date:  2017-04-17

2.  Impact of Coronary Stent Architecture on Clinical Outcomes: Do Minor Changes in Stent Architecture Really Matter?

Authors:  Amin Ariff Bin Nuruddin; Wan Azman Wan Ahmad; Matthias Waliszewski; Tay Mok Heang; Liew Houng Bang; Ahmad Khairuddin Mohamed Yusof; Imran Zainal Abidin; Ahmad Syadi Zuhdi; Florian Krackhardt
Journal:  Cardiol Ther       Date:  2020-12-04
  2 in total