Literature DB >> 21802089

Selective comprehensive multi-dimensional separation for resolution enhancement in high performance liquid chromatography. Part I: principles and instrumentation.

Stephen R Groskreutz1, Michael M Swenson, Laura B Secor, Dwight R Stoll.   

Abstract

An approach to enhancing the resolution of select portions of conventional one-dimensional high performance liquid chromatography (HPLC) separations was developed, which we refer to as selective comprehensive two-dimensional HPLC (sLC×LC). In this first of a series of two papers we describe the principles of this approach, which breaks the long-standing link in on-line multi-dimensional chromatography between the timescales of sampling the first dimension (¹D) separation and the separation of fractions of ¹D effluent in the second dimension. This allows rapid, high-efficiency separations to be used in the first dimension, while still adequately sampling ¹D peaks. Transfer, transient storage, and subsequent second dimension (²D) separations of multiple fractions of a particular ¹D peak produces a two-dimensional chromatogram that reveals the coordinates of the peak in both dimensions of the chromatographic space. Using existing valve technology we find that the approach is repeatable (%RSD of peak area <1.5%), even at very short first dimension sampling times--as low as 1s. We have also systematically studied the critical influence of the volume and composition of fractions transferred from the first to the second dimension of the sLC × LC system with reversed-phase columns in both dimensions, and the second dimension operated isocratically. We find that dilution of the transferred fraction, so that it contains 10-20% less organic solvent than the ²D eluent, generally mitigates the devastating effects of large transfer volumes on ²D performance in this type of system. Several example applications of the sLC × LC approach are described in the second part of this two-part series. We anticipate that future advances in the valve technology used here will significantly widen the scope of possible applications of the sLC × LC approach. Copyright Â
© 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21802089     DOI: 10.1016/j.chroma.2011.06.035

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Improving peak capacity in fast online comprehensive two-dimensional liquid chromatography with post-first-dimension flow splitting.

Authors:  Marcelo R Filgueira; Yuan Huang; Klaus Witt; Cecilia Castells; Peter W Carr
Journal:  Anal Chem       Date:  2011-11-23       Impact factor: 6.986

2.  Semi-automated alignment and quantification of peaks using parallel factor analysis for comprehensive two-dimensional liquid chromatography-diode array detector data sets.

Authors:  Robert C Allen; Sarah C Rutan
Journal:  Anal Chim Acta       Date:  2012-02-19       Impact factor: 6.558

3.  Temperature-assisted on-column solute focusing: a general method to reduce pre-column dispersion in capillary high performance liquid chromatography.

Authors:  Stephen R Groskreutz; Stephen G Weber
Journal:  J Chromatogr A       Date:  2014-05-28       Impact factor: 4.759

Review 4.  Trends in the application of high-resolution mass spectrometry for human biomonitoring: An analytical primer to studying the environmental chemical space of the human exposome.

Authors:  Syam S Andra; Christine Austin; Dhavalkumar Patel; Georgia Dolios; Mahmoud Awawda; Manish Arora
Journal:  Environ Int       Date:  2017-01-04       Impact factor: 9.621

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.