Literature DB >> 21800806

Clinicopathologic correlations of poly-(styrene-b-isobutylene-b-styrene) glaucoma drainage devices of different internal diameters in rabbits.

Esdras A Arrieta1, Mohamed Aly, Richard Parrish, Sander Dubovy, Leonard Pinchuk, Yasushi Kato, Francisco Fantes, Jean-Marie Parel.   

Abstract

BACKGROUND AND
OBJECTIVE: To assess the biocompatibility and intraocular pressure (IOP) lowering effect of a novel glaucoma drainage implant in rabbits.
MATERIALS AND METHODS: Sixteen New Zealand white rabbits received one of three glaucoma drainage implants fabricated from poly-(styrene-b-isobutylene-b-styrene [SIBS]) with an internal diameter of the lumen of either 70 (6 eyes), 100 (6 eyes), or 150 (4 eyes) μm. Clinical follow-up examinations were performed during 6 months and postmortem eyes were studied with light microscopy.
RESULTS: Smaller internal diameter implants were associated with fewer complications. IOP levels were not statistically different among the groups. No eyes developed serious complications. Mild chronic inflammation was observed around the tube using light microscopy.
CONCLUSION: SIBS glaucoma drainage implants did not produce clinically detectable intraocular inflammation in a rabbit model. The 70- and 100-μm SIBS drainage devices demonstrated fewer postoperative complications. IOP levels were not statistically different from control eyes in all groups. Copyright 2011, SLACK Incorporated.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21800806     DOI: 10.3928/15428877-20110603-01

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers Imaging        ISSN: 1542-8877


  12 in total

Review 1.  Polymeric trileaflet prosthetic heart valves: evolution and path to clinical reality.

Authors:  Thomas E Claiborne; Marvin J Slepian; Syed Hossainy; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2012-11       Impact factor: 3.166

Review 2.  Effectiveness and limitations of minimally invasive glaucoma surgery targeting Schlemm's canal.

Authors:  Masayuki Kasahara; Nobuyuki Shoji
Journal:  Jpn J Ophthalmol       Date:  2020-11-05       Impact factor: 2.447

Review 3.  Microinvasive glaucoma surgery: a review and classification of implant-dependent procedures and techniques.

Authors:  Joanna Jabłońska; Katarzyna Lewczuk; Joanna Konopińska; Zofia Mariak; Marek Rękas
Journal:  Acta Ophthalmol       Date:  2021-05-14       Impact factor: 3.988

Review 4.  Glaucoma surgery: taking the sub-conjunctival route.

Authors:  Tarek Shaarawy
Journal:  Middle East Afr J Ophthalmol       Date:  2015 Jan-Mar

Review 5.  Ab externo implantation of the MicroShunt, a poly (styrene-block-isobutylene-block-styrene) surgical device for the treatment of primary open-angle glaucoma: a review.

Authors:  Omar Sadruddin; Leonard Pinchuk; Raymund Angeles; Paul Palmberg
Journal:  Eye Vis (Lond)       Date:  2019-11-15

6.  The use of polyisobutylene-based polymers in ophthalmology.

Authors:  Leonard Pinchuk
Journal:  Bioact Mater       Date:  2021-09-21

7.  Evaluation of the Ultrastructural and In Vitro Flow Properties of the PRESERFLO MicroShunt.

Authors:  Marta Ibarz Barberá; Jose Luis Hernández-Verdejo; Jean Bragard; Javier Burguete; Laura Morales Fernández; Pedro Tañá Rivero; Rosario Gómez de Liaño; Miguel A Teus
Journal:  Transl Vis Sci Technol       Date:  2021-11-01       Impact factor: 3.283

Review 8.  PreserFlo® MicroShunt: An Overview of This Minimally Invasive Device for Open-Angle Glaucoma.

Authors:  Gloria Gambini; Matteo Mario Carlà; Federico Giannuzzi; Tomaso Caporossi; Umberto De Vico; Alfonso Savastano; Antonio Baldascino; Clara Rizzo; Raphael Kilian; Aldo Caporossi; Stanislao Rizzo
Journal:  Vision (Basel)       Date:  2022-02-09

Review 9.  The use of poly(styrene-block-isobutylene-block-styrene) as a microshunt to treat glaucoma.

Authors:  Leonard Pinchuk; Isabelle Riss; Juan F Batlle; Yasushi P Kato; John B Martin; Esdras Arrieta; Paul Palmberg; Richard K Parrish; Bruce A Weber; Yongmoon Kwon; Jean-Marie Parel
Journal:  Regen Biomater       Date:  2016-02-25

Review 10.  The development of a micro-shunt made from poly(styrene-block-isobutylene-block-styrene) to treat glaucoma.

Authors:  Leonard Pinchuk; Isabelle Riss; Juan F Batlle; Yasushi P Kato; John B Martin; Esdras Arrieta; Paul Palmberg; Richard K Parrish; Bruce A Weber; Yongmoon Kwon; Jean-Marie Parel
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2015-09-18       Impact factor: 3.368

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.