Detection of a coronary artery vessel wall: performance of 0.3 mm fine-cell detector computed tomography--a phantom study.

Minoru Yamada1, Masahiro Jinzaki, Yutaka Tanami, Kazuhiro Matsumoto, Akihisa Ueno, Masatake Nukui, Yasuhiro Imai, Yotaro Ishihara, Akihiko Nishide, Kosuke Sasaki, Sachio Kuribayashi.   

Abstract

The purpose of this study was to evaluate whether experimental fine-cell detector computed tomography with a 0.3125 mm cell (0.3 mm cell CT) can improve the detection of coronary vessel walls compared with conventional 64-slice computed tomography with a 0.625 mm cell (0.6 mm cell CT). A coronary vessel wall phantom was scanned using 0.6 mm cell CT and 0.3 mm cell CT. The data for 0.3 mm cell CT were obtained using four protocols: a radiation dose equal, double, triple or quadruple that were used in the 0.6 mm cell CT protocol. The detectable size of the vessel wall was assessed based on the first and second derivative functions, and the minimum measurable values were compared using a paired t-test. As a result, the minimum detectable wall thickness of 0.6 mm cell CT (1.5 mm) was significantly larger than that of 0.3 mm cell CT performed using the triple- and quadruple-dose protocols (0.9 mm) and the double-dose protocol (1.1 mm). The difference in the minimum detectable vessel wall thickness measured using 0.6 mm cell CT (1.5 ± 0.1 mm) and 0.3 mm cell CT (0.9 ± 0.1 mm, 1.1 ± 0.2 mm) was significant (p < 0.01). We concluded that 0.3 mm cell CT improved the detection of coronary vessel walls when a more than double-dose protocol was used compared with 0.6 mm cell CT.

Mesh:

Year:  2011        PMID: 21791729     DOI: 10.1088/0031-9155/56/16/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

Review 1.  Noninvasive Imaging of Atherosclerotic Plaque Progression: Status of Coronary Computed Tomography Angiography.

Authors:  Veit Sandfort; Joao A C Lima; David A Bluemke
Journal:  Circ Cardiovasc Imaging       Date:  2015-07       Impact factor: 7.792

2.  Comparison of the diagnostic accuracy of FBP, ASiR, and MBIR reconstruction during CT angiography in the evaluation of a vessel phantom with calcified stenosis in a distal superficial femoral artery in a cadaver extremity.

Authors:  Jitsuro Tsukada; Minoru Yamada; Yoshitake Yamada; Shun Yamazaki; Nobuaki Imanishi; Kentaro Tamura; Masahiro Hashimoto; Seishi Nakatsuka; Masahiro Jinzaki
Journal:  Medicine (Baltimore)       Date:  2016-07       Impact factor: 1.889

3.  Posture-induced changes in the vessels of the head and neck: evaluation using conventional supine CT and upright CT.

Authors:  Kenzo Kosugi; Yoshitake Yamada; Minoru Yamada; Yoichi Yokoyama; Hirokazu Fujiwara; Keisuke Yoshida; Kazunari Yoshida; Masahiro Toda; Masahiro Jinzaki
Journal:  Sci Rep       Date:  2020-10-06       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.