Literature DB >> 21790992

Assessment of nose protector for sport activities: finite element analysis.

Neide Pena Coto1, Josete Barbosa Cruz Meira, Reinaldo Brito e Dias, Larissa Driemeier, Guilherme de Oliveira Roveri, Pedro Yoshito Noritomi.   

Abstract

There has been a significant increase in the number of facial fractures stemming from sport activities in recent years, with the nasal bone one of the most affected structures. Researchers recommend the use of a nose protector, but there is no standardization regarding the material employed. Clinical experience has demonstrated that a combination of a flexible and rigid layer of ethylene vinyl acetate (EVA) offers both comfort and safety to practitioners of sports. The aim of the present study was the investigation into the stresses generated by the impact of a rigid body on the nasal bone on models with and without an EVA protector. For such, finite element analysis was employed. A craniofacial model was constructed from images obtained through computed tomography. The nose protector was modeled with two layers of EVA (1 mm of rigid EVA over 2 mm of flexible EVA), following the geometry of the soft tissue. Finite element analysis was performed using the LS Dyna program. The bone and rigid EVA were represented as elastic linear material, whereas the soft tissues and flexible EVA were represented as hyperelastic material. The impact from a rigid sphere on the frontal region of the face was simulated with a constant velocity of 20 m s(-1) for 9.1 μs. The model without the protector served as the control. The distribution of maximal stress of the facial bones was recorded. The maximal stress on the nasal bone surpassed the breaking limit of 0.13-0.34 MPa on the model without a protector, while remaining below this limit on the model with the protector. Thus, the nose protector made from both flexible and rigid EVA proved effective at protecting the nasal bones under high-impact conditions.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21790992     DOI: 10.1111/j.1600-9657.2011.01046.x

Source DB:  PubMed          Journal:  Dent Traumatol        ISSN: 1600-4469            Impact factor:   3.333


  3 in total

1.  FDI policy statement on Sports dentistry: Adopted by the FDI General Assembly, September 2016, Poznan, Poland.

Authors: 
Journal:  Int Dent J       Date:  2017-02       Impact factor: 2.607

2.  Does facial soft tissue protect against zygomatic fractures? Results of a finite element analysis.

Authors:  Heike Huempfner-Hierl; Alexander Bohne; Andreas Schaller; Gert Wollny; Thomas Hierl
Journal:  Head Face Med       Date:  2015-06-16       Impact factor: 2.151

3.  Improvement of the Shock Absorption Ability of a Face Guard by Incorporating a Glass-Fiber-Reinforced Thermoplastic and Buffering Space.

Authors:  Takahiro Wada; Hiroshi Churei; Haruka Takayanagi; Naohiko Iwasaki; Toshiaki Ueno; Hidekazu Takahashi; Motohiro Uo
Journal:  Biomed Res Int       Date:  2018-05-08       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.