The rapid shallow breathing index (RSBI) is commonly used clinically for predicting the outcome of weaning from mechanical ventilation. We compared the RSBI and its predictive accuracies measured under 5 ventilatory strategies before weaning trials. Ninety-eight patients were included and divided into successful (n=71) and failed (n=27) groups based on their weaning outcomes. The RSBI was randomly measured when patients spontaneously breathed 21% O2 with no ventilator support (the control strategy) or were connected to ventilator breathing with 21% or 40% O2 and 0 or 5 cm H2O of continuous positive airway pressure (CPAP). We found that the RSBI values did not exhibit significant differences among the 4 ventilator strategies, but all were higher than that of the control; this remained valid in the non-chronic obstructive pulmonary disease (COPD) subgroup, but not in the COPD subgroup. Values of the area under the receiver operating characteristic curve of the RSBI for the 5 strategies were 0.51-0.62 with no significant difference between any 2 strategies. The incidences of adverse reactions (respiratory rate > or =35 breaths/min or oxygen saturation < or =89% for > or =1 min) were relatively high for the 21% O2-0 and 5 cm H2O CPAP groups (20 patients each) and low for the 40% O(2)-5 cmH2O CPAP group (2 patients). We concluded that RSBI values increased with the use of a ventilator, but not with additional applications of 40% 02 and/or 5 cm H2O CPAP. Their accuracies for predicting weaning outcome were unaltered by any of these interventions, but the incidence of adverse reactions increased with the use of the ventilator and decreased with additional 40% O2 supplementation.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21789879     DOI: 10.4077/cjp.2010.amk013

Source DB:  PubMed          Journal:  Chin J Physiol        ISSN: 0304-4920            Impact factor:   1.764


  2 in total

1.  The development of a novel knowledge-based weaning algorithm using pulmonary parameters: a simulation study.

Authors:  Hasan Guler; Ugur Kilic
Journal:  Med Biol Eng Comput       Date:  2017-08-02       Impact factor: 2.602

2.  How Mechanical Ventilation Measurement, Cutoff and Duration Affect Rapid Shallow Breathing Index Accuracy: A Randomized Trial.

Authors:  Elaine Cristina Goncalves; Alessandra Fabiane Lago; Elaine Caetano Silva; Marcelo Barros de Almeida; Anibal Basile-Filho; Ada Clarice Gastaldi
Journal:  J Clin Med Res       Date:  2017-02-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.