Literature DB >> 21789451

Diagnostic accuracy of frozen section tests for surgical diseases.

Rafael Denadai Pigozzi da Silva1, Luís Ricardo Martinhão Souto, Graziela de Macedo Matsushita, Marcus de Medeiros Matsushita.   

Abstract

OBJECTIVE: To evaluate the accuracy of frozen section tests at different anatomical sites performed in an academic department of pathology.
METHODS: We conducted a retrospective study from a computerized database of all frozen section tests. These diagnoses were compared to definite paraffin, used as controls. The tests were divided into three groups: inconclusive, consistent and inconsistent, the latter being subdivided into false positives and false negatives. The main indications for examinations and anatomical sites involved with diagnostic disagreements were also analyzed.
RESULTS: Four hundred and thirty-three specimens were frozen tested, and the main indication was diagnostic (75.75%). In 404 tests (93.30%) diagnoses of biopsies in paraffin and frozen section were consistent. In 20 cases (4.62%) the results of frozen section biopsy were inconclusive and in 9 (2.08%) they were false negative. There were no false positive results. The most commonly assessed organ was the thyroid (25.64%). In the overall analysis, the body region most related with inconclusive diagnoses was the thyroid (seven cases) and in relation to specific sites it was the lungs/pleura/mediastinum (13.33%). Skin was the organ that showed more discordant diagnoses between frozen biopsies and paraffin.
CONCLUSION: The global accuracy of frozen section was 93.30%; for specific anatomical sites, diagnostic accuracy ranged from 86.67% to 100%.

Entities:  

Mesh:

Year:  2011        PMID: 21789451     DOI: 10.1590/s0100-69912011000300002

Source DB:  PubMed          Journal:  Rev Col Bras Cir        ISSN: 0100-6991


  5 in total

1.  Surgical Pathology and Intraoperative Consultation: An Audit.

Authors:  Mostafa Golam; Zarat Queen
Journal:  Malays J Med Sci       Date:  2015 Jul-Aug

2.  The Diagnostic Accuracy of Frozen Section Compared to Permanent Section: A Single Center Study in Iran.

Authors:  Hossein Hatami; Zhaleh Mohsenifar; Seyed Navid Alavi
Journal:  Iran J Pathol       Date:  2015

3.  Comparative study of laser-induced choroidal neovascularization in rats by paraffin sections, frozen sections and high-resolution optical coherence tomography.

Authors:  Jian Jiao; Bin Mo; Hang Wei; Yan-rong Jiang
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-11-23       Impact factor: 3.117

4.  Sensitivity and specificity of frozen section diagnosis in orbital and adnexal malignancies.

Authors:  Md Shahid Alam; Andrea Tongbram; Subramanian Krishnakumar; Jyotirmay Biswas; Bipasha Mukherjee
Journal:  Indian J Ophthalmol       Date:  2019-12       Impact factor: 1.848

5.  Accuracy of Frozen Section with Histopathological Report in an Institute.

Authors:  Purbesh Adhikari; Paricha Upadhyaya; Smriti Karki; Chandra Shekhar Agrawal; Shyam Thapa Chettri; Ajay Agrawal
Journal:  JNMA J Nepal Med Assoc       Date:  2018 Mar-Apr       Impact factor: 0.406