Literature DB >> 21788686

Limitations of temperature measurement in the aural canal with an ear mould integrated sensor.

L P J Teunissen1, A de Haan, J J de Koning, H E Clairbois, H A M Daanen.   

Abstract

Aural canal temperature measurement using an ear mould integrated sensor (T(ac)) might be a method suited for continuous non-invasive core temperature estimation in operational settings. We studied the effect of ambient temperature, wind and high intensity exercise on T(ac) and its ability to predict esophageal (T(es)) and rectal temperatures (T(re)). Seven subjects performed a protocol of rest at 21, 10 and 30 °C, followed by exercise and recovery at 30 °C. The subjects performed the protocol twice: with and without face-wind from halfway through the 30 °C rest period. Extra auricle insulation was applied at one side. Ambient temperature changes affected T(ac) significantly, while T(es) and T(re) remained stable. Insulating the auricle reduced but did not abolish this effect. Wind had an immediate cooling effect on T(ac) independent of auricle insulation. During exercise and recovery in 30 °C, T(ac) provided acceptable group predictions of T(re) in trials without wind (bias: -0.66 ± 0.21 °C covered, -1.20 ± 0.15 °C uncovered). Bias was considerably higher with wind, but variability was similar (-1.73 ± 0.11 °C covered, -2.49 ± 0.04 °C uncovered). Individual predictions of T(es) and T(re) showed more variation, especially with wind. We conclude that T(ac) may be used for core temperature assessment of groups in warm and stable conditions.

Entities:  

Mesh:

Year:  2011        PMID: 21788686     DOI: 10.1088/0967-3334/32/9/004

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  4 in total

1.  Hearables: New Perspectives and Pitfalls of In-Ear Devices for Physiological Monitoring. A Scoping Review.

Authors:  Michela Masè; Alessandro Micarelli; Giacomo Strapazzon
Journal:  Front Physiol       Date:  2020-10-16       Impact factor: 4.566

2.  Climate Warming and Occupational Heat and Hot Environment Standards in Thailand.

Authors:  Wantanee Phanprasit; Kannikar Rittaprom; Sumitra Dokkem; Aronrag C Meeyai; Vorakamol Boonyayothin; Jouni J K Jaakkola; Simo Näyhä
Journal:  Saf Health Work       Date:  2020-09-25

3.  Influence of low ambient temperature on epitympanic temperature measurement: a prospective randomized clinical study.

Authors:  Giacomo Strapazzon; Emily Procter; Gabriel Putzer; Giovanni Avancini; Tomas Dal Cappello; Norbert Überbacher; Georg Hofer; Bernhard Rainer; Georg Rammlmair; Hermann Brugger
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2015-11-05       Impact factor: 2.953

Review 4.  Optical Fiber Temperature Sensors and Their Biomedical Applications.

Authors:  Paulo Roriz; Susana Silva; Orlando Frazão; Susana Novais
Journal:  Sensors (Basel)       Date:  2020-04-09       Impact factor: 3.576

  4 in total