AIMS: We evaluated the effect of pulmonary vein (PV) anatomical characteristics on PV isolation (PVI) and long-term efficacy of ablation with phased radiofrequency (RF) energy and pulmonary vein ablation catheter (PVAC) multi-electrode catheter. METHODS AND RESULTS: Before the procedure, PV anatomy was visualized by magnetic resonance imaging (MRI). Consecutive patients with paroxysmal atrial fibrillation were treated with the PVAC with successful acute isolation. Follow-up was performed at 3, 6, and 12 months with electrocardiogram and 7-day Holter recording at 6 and/or 12 months. Symptomatic patients received additional event recording. In 110 patients a pre-procedure cardiac MRI was performed. Ninety-seven (88%) had a separate left superior PV and separate left inferior PV, all patients had a separate right superior PV and separate right inferior PV. Fourteen (13%) had a left PV with common trunk and 27 (25%) had a separate right middle PV (RMPV). After a follow-up of 1 year, 57 of 110 (52%) patients were free of AF without anti-arrhythmic drug. No specific anatomical variable that was related to long-term failure could be found. There was a trend for patients with larger veins (>24 mm) or separate RMPV to have a lower efficacy. The number of applications per vein or procedure did not influence long-term outcome. CONCLUSIONS: In patients who have undergone PVI with phased RF energy and PVAC multi-electrode ablation, long-term efficacy is not significantly affected by PV anatomy or number of applications, although a trend for reduced efficacy is seen for PV with diameter >24 mm, and presence of RMPV.
AIMS: We evaluated the effect of pulmonary vein (PV) anatomical characteristics on PV isolation (PVI) and long-term efficacy of ablation with phased radiofrequency (RF) energy and pulmonary vein ablation catheter (PVAC) multi-electrode catheter. METHODS AND RESULTS: Before the procedure, PV anatomy was visualized by magnetic resonance imaging (MRI). Consecutive patients with paroxysmal atrial fibrillation were treated with the PVAC with successful acute isolation. Follow-up was performed at 3, 6, and 12 months with electrocardiogram and 7-day Holter recording at 6 and/or 12 months. Symptomatic patients received additional event recording. In 110 patients a pre-procedure cardiac MRI was performed. Ninety-seven (88%) had a separate left superior PV and separate left inferior PV, all patients had a separate right superior PV and separate right inferior PV. Fourteen (13%) had a left PV with common trunk and 27 (25%) had a separate right middle PV (RMPV). After a follow-up of 1 year, 57 of 110 (52%) patients were free of AF without anti-arrhythmic drug. No specific anatomical variable that was related to long-term failure could be found. There was a trend for patients with larger veins (>24 mm) or separate RMPV to have a lower efficacy. The number of applications per vein or procedure did not influence long-term outcome. CONCLUSIONS: In patients who have undergone PVI with phased RF energy and PVAC multi-electrode ablation, long-term efficacy is not significantly affected by PV anatomy or number of applications, although a trend for reduced efficacy is seen for PV with diameter >24 mm, and presence of RMPV.
Authors: Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; Jose Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber Journal: J Interv Card Electrophysiol Date: 2012-03 Impact factor: 1.900
Authors: Maryam E Rettmann; David R Holmes; Jerome F Breen; Xin Ge; Ronald A Karwoski; Kristi H Monahan; Tristram D Bahnson; Douglas L Packer; Richard A Robb Journal: Comput Methods Programs Biomed Date: 2014-11-13 Impact factor: 5.428
Authors: Maryam E Rettmann; Mia S Gunawan; David R Holmes; Jerome F Breen; Douglas L Packer; Richard A Robb Journal: Acad Radiol Date: 2012-08-11 Impact factor: 3.173
Authors: J C Balt; S Karadavut; A A W Mulder; J G L M Luermans; M C E F Wijffels; L V A Boersma Journal: J Interv Card Electrophysiol Date: 2013-05-01 Impact factor: 1.900
Authors: Petr Kuchynka; Jana Podzimkova; Martin Masek; Lukas Lambert; Vladimir Cerny; Barbara Danek; Tomas Palecek Journal: Biomed Res Int Date: 2015-07-07 Impact factor: 3.411