Literature DB >> 21784649

Boron neutron capture in prostate cancer cells.

Linda Yasui1, Thomas Kroc, Samantha Gladden, Christine Andorf, Sajit Bux, Narayan Hosmane.   

Abstract

A modified enhanced thermal neutron beam (METNB) assembly at Fermilab was used to irradiate borylphenylalanine (BPA) treated human prostate cancer cells, DU 145. Acceptable cellular uptake levels of BPA and no BPA cytotoxicity were observed. In the absence of BPA, the relative biological effectiveness (RBE) of the METNB was determined to be 2.3-4.8 times greater than gamma rays. An additional 1.2 or 1.4 fold relative enhancement from boron neutron capture (RE(BNC)) was observed for METNB irradiated DU 145 cells treated with 4.9 or 12mM BPA, respectively. The additional cell killing of the BPA loaded DU 145 cells by the METNB at Fermilab is evidence for a BNC enhanced cell killing.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21784649     DOI: 10.1016/j.apradiso.2011.07.001

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  4 in total

Review 1.  Boron chemicals in diagnosis and therapeutics.

Authors:  Bhaskar C Das; Pritam Thapa; Radha Karki; Caroline Schinke; Sasmita Das; Suman Kambhampati; Sushanta K Banerjee; Peter Van Veldhuizen; Amit Verma; Louis M Weiss; Todd Evans
Journal:  Future Med Chem       Date:  2013-04       Impact factor: 3.808

2.  Feasibility study on the use of 230 MeV proton cyclotron in proton therapy centers as a spallation neutron source for BNCT.

Authors:  E Nobakht; N Fouladi
Journal:  Rep Pract Oncol Radiother       Date:  2019-10-30

3.  The Anti-Proliferative Effect of Boron Neutron Capture Therapy in a Prostate Cancer Xenograft Model.

Authors:  Kiyoshi Takahara; Teruo Inamoto; Koichiro Minami; Yuki Yoshikawa; Tomoaki Takai; Naokazu Ibuki; Hajime Hirano; Hayahito Nomi; Shinji Kawabata; Satoshi Kiyama; Shin-Ichi Miyatake; Toshihiko Kuroiwa; Minoru Suzuki; Mitsunori Kirihata; Haruhito Azuma
Journal:  PLoS One       Date:  2015-09-01       Impact factor: 3.240

4.  First experimental proof of Proton Boron Capture Therapy (PBCT) to enhance protontherapy effectiveness.

Authors:  G A P Cirrone; L Manti; D Margarone; G Petringa; L Giuffrida; A Minopoli; A Picciotto; G Russo; F Cammarata; P Pisciotta; F M Perozziello; F Romano; V Marchese; G Milluzzo; V Scuderi; G Cuttone; G Korn
Journal:  Sci Rep       Date:  2018-01-18       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.