Literature DB >> 21784393

Comparison of severity of aortic regurgitation by cardiovascular magnetic resonance versus transthoracic echocardiography.

Ruvin S Gabriel1, Rahul Renapurkar, Michael A Bolen, David Verhaert, Michael Leiber, Scott D Flamm, Brian P Griffin, Milind Y Desai.   

Abstract

Transthoracic echocardiography is the current standard for assessing aortic regurgitation (AR). AR severity can also be evaluated by flow measurement in the ascending aorta using cardiac magnetic resonance (CMR); however, the optimal site for flow measurement and the regurgitant fraction (RF) severity grading criteria that best compares with the transthoracic echocardiographic assessment of AR are not clear. The present study aimed to determine the optimal site and RF grading criteria for AR severity using phase-contrast flow measurements and CMR. A prospective observational study was performed of 107 consecutive patients who were undergoing CMR of the thoracic aorta. Using CMR, the AR severity and aortic dimensions were measured at 3 levels in the aorta (the sinotubular junction, mid-ascending aorta, and distal ascending aorta). The results were compared to the transthoracic echocardiographic grade of AR severity using multiple qualitative and quantitative criteria (grade 0, none; I+, mild; II+, mild to moderate; III+, moderate to severe; and IV+, severe). The mean RF values were significantly greater at the sinotubular junction than at the distal ascending aorta (13 ± 13.3% vs 9.4 ± 12.6%, respectively; p <0.001). The RF values that best defined AR severity using phase-contrast CMR were as follows: grade 0 to I+, <8%; grade II+, 8% to 19%; grade III+, 20 to 29%; and grade IV+, 30%) at the sinotubular or mid-ascending aorta. In conclusion, the quantitative RF values of AR severity using phase-contrast flow are best assessed in the proximal ascending aorta and differ from recognized quantitative echocardiographic criteria.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21784393     DOI: 10.1016/j.amjcard.2011.05.034

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  15 in total

1.  The Brazilian Society of Cardiology and Brazilian Society of Exercise and Sports Medicine Updated Guidelines for Sports and Exercise Cardiology - 2019.

Authors:  Nabil Ghorayeb; Ricardo Stein; Daniel Jogaib Daher; Anderson Donelli da Silveira; Luiz Eduardo Fonteles Ritt; Daniel Fernando Pellegrino Dos Santos; Ana Paula Rennó Sierra; Artur Haddad Herdy; Claúdio Gil Soares de Araújo; Cléa Simone Sabino de Souza Colombo; Daniel Arkader Kopiler; Filipe Ferrari Ribeiro de Lacerda; José Kawazoe Lazzoli; Luciana Diniz Nagem Janot de Matos; Marcelo Bichels Leitão; Ricardo Contesini Francisco; Rodrigo Otávio Bougleux Alô; Sérgio Timerman; Tales de Carvalho; Thiago Ghorayeb Garcia
Journal:  Arq Bras Cardiol       Date:  2019-03       Impact factor: 2.000

2.  Direct measurement of aortic regurgitation with phase-contrast magnetic resonance is inaccurate: proposal of an alternative method of quantification.

Authors:  Yoichi Iwamoto; Akio Inage; George Tomlinson; Kyong Jin Lee; Lars Grosse-Wortmann; Mike Seed; Andrea Wan; Shi-Joon Yoo
Journal:  Pediatr Radiol       Date:  2014-06-18

Review 3.  How to Image and Manage Prosthesis-Related Complications After Transcatheter Aortic Valve Replacement.

Authors:  Nina C Wunderlich; Jörg Honold; Martin J Swaans; Robert J Siegel
Journal:  Curr Cardiol Rep       Date:  2021-07-01       Impact factor: 2.931

4.  Assessment of Aortic Valve Disease: Role of Imaging Modalities.

Authors:  Romain Capoulade; Philippe Pibarot
Journal:  Curr Treat Options Cardiovasc Med       Date:  2015-11

Review 5.  Current Management of Patients with Severe Aortic Regurgitation.

Authors:  Charles Nadeau-Routhier; Ons Marsit; Jonathan Beaudoin
Journal:  Curr Treat Options Cardiovasc Med       Date:  2017-02

6.  Comprehensive MR Analysis of Cardiac Function, Aortic Hemodynamics and Left Ventricular Strain in Pediatric Cohort with Isolated Bicuspid Aortic Valve.

Authors:  Heather A Stefek; Haben Berhane; Joshua D Robinson; Brian Reilly; Alexander Ruh; Michael Markl; Cynthia K Rigsby
Journal:  Pediatr Cardiol       Date:  2019-07-24       Impact factor: 1.655

7.  Quantitative assessment of paravalvular regurgitation following transcatheter aortic valve replacement.

Authors:  Gareth Crouch; Phillip J Tully; Jayme Bennetts; Ajay Sinhal; Craig Bradbrook; Amy L Penhall; Carmine G De Pasquale; Robert A Baker; Joseph B Selvanayagam
Journal:  J Cardiovasc Magn Reson       Date:  2015-05-08       Impact factor: 5.364

8.  The role of cardiovascular magnetic resonance in stratifying paravalvular leak severity after transcatheter aortic valve replacement: an observational outcome study.

Authors:  Gregory R Hartlage; Vasilis C Babaliaros; Vinod H Thourani; Salim Hayek; Christina Chrysohoou; Nima Ghasemzadeh; Arthur E Stillman; Stephen D Clements; John N Oshinski; Stamatios Lerakis
Journal:  J Cardiovasc Magn Reson       Date:  2014-12-05       Impact factor: 5.364

Review 9.  The Role of Imaging in Aortic Valve Disease.

Authors:  Russell J Everett; David E Newby; Andrew Jabbour; Zahi A Fayad; Marc R Dweck
Journal:  Curr Cardiovasc Imaging Rep       Date:  2016-06-07

10.  Clinical use of 4D flow MRI for quantification of aortic regurgitation.

Authors:  Ana Alvarez; Vicente Martinez; Gonzalo Pizarro; Manuel Recio; Jose Ángel Cabrera
Journal:  Open Heart       Date:  2020-02-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.