Literature DB >> 21783115

Influence of occlusal geometry on ceramic crown fracture; role of cusp angle and fissure radius.

Tanapon Sornsuwan1, Michael V Swain.   

Abstract

OBJECTIVES: To develop an approximate analytical model that identifies the influence of both cusp angle and notch radius on the failure load of all-ceramic premolar crowns.
METHODS: The scatter of failure loads in a crown fracture resistance test was analyzed based on the stress intensity and stress concentration factors from mechanics models developed for simple compact tension to more sophisticated blunt V-notch specimens. Based on the same loading conditions and dimensions, the predicted loads were systematically compared with fracture loads of laboratory-tested crowns to identify the most relevant model. Finally, based upon these models a safe range of cusp angles and notch radii were identified for posterior all-ceramic crowns with various veneering materials' fracture toughness values as the selection criteria.
RESULTS: The failure loads of the crowns were distributed in the range between the classical compact tension (lower bound) and blunt V-notch model (upper bound). Additionally, when considering the effect of different materials, the predicted trend of failure loads moves to higher loads well above typical occlusal forces when the fracture toughness of veneering porcelain is increased. The effects of notch radius on the failure load are still inconclusive due to the relatively complex shape of occlusal surfaces. Further studies on crowns with a range of material properties are required to substantiate the model. SIGNIFICANCE: Cusp angle is a key factor that controls the stress generated at the crown fissure. This study provides the rationale for evaluating such effects and clinical guidelines for occlusal design are proposed. Crown
Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21783115     DOI: 10.1016/j.jmbbm.2011.03.014

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  4 in total

1.  Influence of cusp inclination and curvature on the in vitro failure and fracture resistance of veneered zirconia crowns.

Authors:  Verena Preis; Thomas Dowerk; Michael Behr; Carola Kolbeck; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2013-07-12       Impact factor: 3.573

2.  Glass Ceramic CAD/CAM crowns and severely altered posterior teeth: a three levels study.

Authors:  Michel Fages; Stephane Corn; Pierre Slangen; Jacques Raynal; Patrick Ienny; Kinga Turzo; Frederic Cuisinier; Jean-Cédric Durand
Journal:  J Mater Sci Mater Med       Date:  2017-08-19       Impact factor: 3.896

3.  Modelling of stress distribution and fracture in dental occlusal fissures.

Authors:  Boyang Wan; Mahdi Shahmoradi; Zhongpu Zhang; Yo Shibata; Babak Sarrafpour; Michael Swain; Qing Li
Journal:  Sci Rep       Date:  2019-03-18       Impact factor: 4.379

4.  Effect of occlusal anatomy of CAD/CAM feldspathic posterior crowns in the stress concentration and fracture load.

Authors:  Alexandre Luiz Souto Borges; João Paulo Mendes Tribst; Aline Lins de Lima; Amanda Maria de Oliveira Dal Piva; Mutlu Özcan
Journal:  Clin Exp Dent Res       Date:  2021-07-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.