Literature DB >> 21782470

Accuracy of the biceps tendon sheath injection: ultrasound-guided or unguided injection? A randomized controlled trial.

Tomohisa Hashiuchi1, Goro Sakurai, Mitsutoshi Morimoto, Tatsuya Komei, Yoshinori Takakura, Yasuhito Tanaka.   

Abstract

BACKGROUND: Patients often localize pain in the anterior shoulder; however, this patient-localized pain does not necessarily correlate to the location of disease. Unguided shoulder injections are common in clinical practice. The accuracy of unguided biceps tendon sheath injections has not been studied. Patient management may be aided by the knowledge of injection accuracy. This study compared the accuracy of ultrasound-guided biceps tendon sheath injection with unguided injection.
MATERIALS AND METHODS: The study comprised 30 patients (30 shoulders) with reported anterior shoulder pain who had a primary diagnosis of tenosynovitis or tendinitis of the biceps tendon, or both. Shoulders were randomly allocated into ultrasound-guided and unguided injection groups. Computed tomography (CT) imaging was performed immediately after a contrast agent was injected into the biceps tendon sheath. The locations of contrast seen on CT scan were classified into 3 types: only within the tendon sheath (type 1); inside the tendon, tendon sheath, and surrounding area (type 2); and only the area outside the tendon sheath (type 3).
RESULTS: Ultrasound-guided injections resulted in 86.7% type 1 and 13.3% type 2 locations. Unguided injections resulted in 26.7% type 1, 40.0% type 2, and 33.3% type 3 locations. The difference for each location type was significant (P < .05).
CONCLUSION: Injection into the tendon sheath of the long head of the biceps brachii can be more accurately performed using ultrasound guidance than by the blind method.
Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21782470     DOI: 10.1016/j.jse.2011.04.004

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  15 in total

1.  CORR Insights®: Does the use of ultrasound affect contamination of musculoskeletal injections sites?

Authors:  R Michael Gross
Journal:  Clin Orthop Relat Res       Date:  2014-09-16       Impact factor: 4.176

2.  Clinical indications for image-guided interventional procedures in the musculoskeletal system: a Delphi-based consensus paper from the European Society of Musculoskeletal Radiology (ESSR)-part I, shoulder.

Authors:  Luca Maria Sconfienza; Miraude Adriaensen; Domenico Albano; Georgina Allen; Maria Pilar Aparisi Gómez; Alberto Bazzocchi; Ian Beggs; Bianca Bignotti; Vito Chianca; Angelo Corazza; Danoob Dalili; Miriam De Dea; Jose Luis Del Cura; Francesco Di Pietto; Eleni Drakonaki; Fernando Facal de Castro; Dimitrios Filippiadis; Jan Gielen; Salvatore Gitto; Harun Gupta; Andrea S Klauser; Radhesh Lalam; Silvia Martin; Carlo Martinoli; Giovanni Mauri; Catherine McCarthy; Eugene McNally; Kalliopi Melaki; Carmelo Messina; Rebeca Mirón Mombiela; Benedikt Neubauer; Cyprian Olchowy; Davide Orlandi; Athena Plagou; Raquel Prada Gonzalez; Saulius Rutkauskas; Ziga Snoj; Alberto Stefano Tagliafico; Alexander Talaska; Violeta Vasilevska-Nikodinovska; Jelena Vucetic; David Wilson; Federico Zaottini; Marcello Zappia; Marina Obradov
Journal:  Eur Radiol       Date:  2019-09-16       Impact factor: 5.315

Review 3.  A practical, evidence-based, comprehensive (PEC) physical examination for diagnosing pathology of the long head of the biceps.

Authors:  Samuel Rosas; Michael K Krill; Kelms Amoo-Achampong; KiHyun Kwon; Benedict U Nwachukwu; Frank McCormick
Journal:  J Shoulder Elbow Surg       Date:  2017-05-04       Impact factor: 3.019

4.  The "injection jet sign": an innovative method of needle position confirmation during ultrasound guided injections.

Authors:  Judah Goldschmiedt; Chaitanya Shilagani; Himanshu Patel
Journal:  Skeletal Radiol       Date:  2017-01-27       Impact factor: 2.199

5.  Interventional therapeutic procedures in the musculoskeletal system: an Italian Survey by the Italian College of Musculoskeletal Radiology.

Authors:  Enzo Silvestri; Antonio Barile; Domenico Albano; Carmelo Messina; Davide Orlandi; Angelo Corazza; Luigi Zugaro; Carlo Masciocchi; Luca Maria Sconfienza
Journal:  Radiol Med       Date:  2017-12-16       Impact factor: 3.469

6.  Ultrasound-guided versus palpation-guided corticosteroid injections for tendinosis of the long head of the biceps: A randomized comparative study.

Authors:  Christos K Yiannakopoulos; Panayiotis D Megaloikonomos; Konstantina Foufa; John Gliatis
Journal:  Skeletal Radiol       Date:  2019-11-12       Impact factor: 2.199

Review 7.  [Injuries of the biceps-labrum complex : Principles, pathologies and treatment concepts].

Authors:  N Hawi; P Habermeyer; R Meller; S Razaeian; C von Falck; C Krettek
Journal:  Unfallchirurg       Date:  2020-12-10       Impact factor: 1.000

Review 8.  Existing Evidence on Ultrasound-Guided Injections in Sports Medicine.

Authors:  Eldra W Daniels; David Cole; Bret Jacobs; Shawn F Phillips
Journal:  Orthop J Sports Med       Date:  2018-02-22

9.  Do we really need to order magnetic resonance imaging? Shoulder surgeon ultrasound practice patterns and beliefs.

Authors:  Kevin K Kruse; Matthew F Dilisio; William L Wang; Christopher C Schmidt
Journal:  JSES Open Access       Date:  2019-04-26

10.  Long head of the biceps pathology combined with rotator cuff tears.

Authors:  Konstantinos Ditsios; Filon Agathangelidis; Achilleas Boutsiadis; Dimitrios Karataglis; Pericles Papadopoulos
Journal:  Adv Orthop       Date:  2012-11-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.